Loading (50 kb)...'
(continued)
units
(pounds
per 1,000
lb of
product)
-----------------------------
TSS....................................... 45 36
Oil and grease............................ 2.2 1.7
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55792, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]
§ 408.256 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55792, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.257 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
Except as provided in §§125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:
------------------------------------------------------------------------
Effluent limitations
-------------------------
Average of
daily
Effluent characteristic values for
Maximum for thirty
any 1 day consecutive
days shall
not exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-------------------------
TSS........................................... 45 36
Oil and grease................................ 2.2 1.7
pH............................................ (\1\) (\1\)
-------------------------
English
units
(pounds per
1,000 lb of
product)
-------------------------
TSS........................................... 45 36
Oil and grease................................ 2.2 1.7
pH............................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[51 FR 24998, July 9, 1986]
Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory
top
Source: 40 FR 55793, Dec. 1, 1975, unless otherwise noted.
§ 408.260 Applicability; description of the Atlantic and Gulf Coast hand-shucked oyster processing subcategory.
top
The provisions of this subpart are applicable to discharge resulting from existing hand-shucked oyster processing facilities on the Atlantic and Gulf Coasts which process more than 454 kg (1000 lbs) of product per day on any day during a calendar year and all new sources.
§ 408.261 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean the weight of the oyster meat after shucking.
§ 408.262 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-----------------------------
TSS....................................... 24 16
Oil and grease............................ 1.2 0.81
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
product)
-----------------------------
TSS....................................... 24 16
Oil and grease............................ 1.2 0.81
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55793, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR 33947, June 29, 1995]
§ 408.263 [Reserved]
top
§ 408.264 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55793, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.265 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-----------------------------
TSS....................................... 23 16
Oil and grease............................ 1.1 0.77
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
product)
-----------------------------
TSS....................................... 23 16
Oil and grease............................ 1.1 0.77
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55793, Dec. 1, 1975, as amended at 41 FR 31824, July 30, 1976]
§ 408.266 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55793, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.267 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
Except as provided in §§125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:
------------------------------------------------------------------------
Effluent limitations
-------------------------
Average of
daily
Effluent characteristic values for
Maximum for thirty
any 1 day consecutive
days shall
not exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-------------------------
TSS........................................... 23 16
Oil and grease................................ 1.1 0.77
pH............................................ (\1\) (\1\)
-------------------------
English
units
(pounds per
1,000 lb of
product)
-------------------------
TSS........................................... 23 16
Oil and grease................................ 1.1 0.77
pH............................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[51 FR 24998, July 9, 1986]
Subpart AA—Steamed and Canned Oyster Processing Subcategory
top
Source: 40 FR 55794, Dec. 1, 1975, unless otherwise noted.
§ 408.270 Applicability; description of the steamed and canned oyster processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from oysters which are mechanically shucked.
§ 408.271 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean the weight of the oyster meat after shucking.
§ 408.272 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
TSS....................................... 270 190
Oil and grease............................ 2.3 1.7
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
product)
-----------------------------
TSS....................................... 270 190
Oil and grease............................ 2.3 1.7
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.273 [Reserved]
top
§ 408.274 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.275 Standards of performance for new sources.
top
Except for those steamed and canned oyster processing facilities which utilize air flotation treatment systems to meet the shrimp processing standards of performance for new sources under §§408.115, 408.125, or §408.135 and for which standards of performance should be derived on a case-by-case basis, the following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
BOD5...................................... 67 17
TSS....................................... 56 39
Oil and grease............................ 0.84 0.42
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
product)
-----------------------------
BOD5...................................... 67 17
TSS....................................... 56 39
Oil and grease............................ 0.64 0.42
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55794, Dec. 1, 1975, as amended at 42 FR 6813, Feb. 4, 1977]
§ 408.276 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.277 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.272 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart AB—Sardine Processing Subcategory
top
Source: 40 FR 55795, Dec. 1, 1975, unless otherwise noted.
§ 408.280 Applicability; description of the sardine processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the canning of sardines or sea herring for sardines. These provisions, however, do not cover the relatively new steaking operation in which cutting machines are used for preparing fish steaks.
§ 408.281 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analyses set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.282 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any sardine processing facility which utilizes dry transportation systems from the fish storage area to the fish processing area shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 36 10
Oil and grease............................ 3.5 1.4
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 36 10
Oil and grease............................ 3.5 1.4
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any sardine processing facility not covered under §408.282(a) shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 48 16
Oil and grease............................ 6.3 2.8
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 48 16
Oil and grease............................ 6.3 2.8
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.283 [Reserved]
top
§ 408.284 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.285 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 36 10
Oil and grease............................ 1.4 0.57
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 36 10
Oil and grease............................ 1.4 0.57
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 408.286 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.287 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.282 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart AC—Alaskan Scallop Processing Subcategory
top
Source: 40 FR 55796, Dec. 1, 1975, unless otherwise noted.
§ 408.290 Applicability; description of the Alaskan scallop processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of scallops in Alaska.
§ 408.291 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean the weight of the scallop meat after processing.
§ 408.292 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
TSS....................................... 6.6 1.4
Oil and grease............................ 7.7 0.24
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
product)
-----------------------------
TSS....................................... 6.0 1.4
Oil and grease............................ 7.7 0.24
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any Alaskan scallop processing facility not covered under §408.292(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm. (0.5 inch) in any dimension.
[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.293 [Reserved]
top
§ 408.294 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.295 Standards of performance for new sources.
top
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(1) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
TSS....................................... 5.7 1.4
Oil and grease............................ 7.3 0.23
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
product)
-----------------------------
TSS....................................... 5.7 1.4
Oil and grease............................ 7.3 0.23
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(2) Any Alaskan scallop processing facility not covered under §408.295(a) (1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
(b) [Reserved]
§ 408.296 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.297 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
(a) [Reserved]
(b) Except as provided in §§125.30 through 125.32, any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degreee of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.292(b)(2) of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24998, July 9, 1986]
Subpart AD—Non-Alaskan Scallop Processing Subcategory
top
Source: 40 FR 55797, Dec. 1, 1975, unless otherwise noted.
§ 408.300 Applicability; description of the non-Alaskan scallop processing subcategory.
top
With the exception of land-based processing of calico scallops, the provisions of this subpart are applicable to discharges resulting from the processing of scallops outside of Alaska.
§ 408.301 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean the weight of the scallop meat after processing.
§ 408.302 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
TSS....................................... 6.0 1.4
Oil and grease............................ 7.7 0.24
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
product)
-----------------------------
TSS....................................... 6.0 1.4
Oil and grease............................ 7.7 0.24
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.303 [Reserved]
top
§ 408.304 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]
§ 408.305 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-----------------------------
TSS....................................... 5.7 1.4
Oil and grease............................ 7.3 0.23
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
ofproduct) (continued)