CCLME.ORG - 40 CFR PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY
Loading (50 kb)...'
(continued) product)
-----------------------------
TSS....................................... 5.7 1.4
Oil and grease............................ 7.3 0.23
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 408.306 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]

§ 408.307 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
Except as provided in §§125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:



------------------------------------------------------------------------
Efflluent limitations
-------------------------
Average of
daily
Effuent characteristic values for
Maximum for thirty
any 1 day consecutive
days shall
not exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
product)
-------------------------
TSS........................................... 5.7 1.4
Oil and grease................................ 7.3 0.23
pH............................................ (\1\) (\1\)
-------------------------
English
units
(pounds per
1,000 lb of
product)
-------------------------
TSS........................................... 5.7 1.4
Oil and grease................................ 7.3 0.23
pH............................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[51 FR 24998, July 9, 1986]

Subpart AE—Alaskan Herring Fillet Processing Subcategory
top
Source: 40 FR 55798, Dec. 1, 1975, unless otherwise noted.

§ 408.310 Applicability; description of the Alaskan herring fillet processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of herring fillets in Alaska.

§ 408.311 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.

§ 408.312 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 32 24
Oil and grease............................ 27 10
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 32 24
Oil and grease............................ 27 10
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


(b) Any Alaskan herring fillet processing facility not covered under §408.312(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.

[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]

§ 408.313 [Reserved]
top
§ 408.314 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]

§ 408.315 Standards of performance for new sources.
top
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

(1) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 23 18
Oil and grease............................ 20 7.3
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 23 18
Oil and grease............................ 20 7.3
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


(2) Any Alaskan herring fillet proc-essing facility not covered under §408.315(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.

(b) [Reserved]

§ 408.316 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.317 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.312 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 24997, July 9, 1986]

Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory
top
Source: 40 FR 55799, Dec. 1, 1975, unless otherwise noted.

§ 408.320 Applicability; description of the non-Alaskan herring fillet processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of herring fillets outside of Alaska.

§ 408.321 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.

§ 408.322 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 32 24
Oil and grease............................ 27 10
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 32 24
Oil and grease............................ 27 10
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.323 [Reserved]
top
§ 408.324 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.325 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
BOD5...................................... 16 15
TSS....................................... 7.0 5.2
Oil and grease............................ 2.9 1.1
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
BOD5...................................... 16 15
TSS....................................... 7.0 5.2
Oil and grease............................ 2.9 1.1
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 408.326 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.327 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.322 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 24997, July 9, 1986]

Subpart AG—Abalone Processing Subcategory
top
Source: 40 FR 55800, Dec. 1, 1975, unless otherwise noted.

§ 408.330 Applicability; description of the abalone processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of abalone in the contiguous states.

§ 408.331 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.

§ 408.332 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 27 15
Oil and grease............................ 2.2 1.4
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 27 15
Oil and grease............................ 2.2 1.4
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.333 [Reserved]
top
§ 408.334 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.335 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------





------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 26 14
Oil and grease............................ 2.1 1.3
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 26 14
Oil and grease............................ 2.1 1.3
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 408.336 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------


[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§ 408.337 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
Except as provided in §§125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:



------------------------------------------------------------------------
Efflluent limitations
-------------------------
Average of
daily
Effluent characteristic values for
Maximum for thirty
any 1 day consecutive
days shall
not exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-------------------------
TSS........................................... 26 14
Oil and grease................................ 21 1.3
pH............................................ (\1\) (\1\)
-------------------------
English
units
(pounds per
1,000 lb of
seafood)
-------------------------
TSS........................................... 26 14
Oil and grease................................ 2.1 1.3
pH............................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[51 FR 24999, July 9, 1986]