Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 3.1 1.9
Oil and grease............................ 4.3 0.56
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 3.1 1.9
Oil and grease............................ 4.3 0.56
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any Alaskan bottom-fish processing facility not covered under §408.202(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.203 [Reserved]
top
§ 408.204 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.205 Standards of performance for new sources.
top
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(1) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 1.9 1.1
Oil and grease............................ 2.6 0.34
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 1.9 1.1
Oil and grease............................ 2.6 0.34
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(2) Any Alaskan bottom-fish processing facility not covered under §408.205(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
(b) [Reserved]
§ 408.206 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.207 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
(a) [Reserved]
(b) Except as provided in §§125.30 through 125.32, any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.202(b)(2) of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24998, July 9, 1986]
Subpart U—Non-Alaskan Conventional Bottom Fish Processing Subcategory
top
Source: 40 FR 55788, Dec. 1, 1975, unless otherwise noted.
§ 408.210 Applicability; description of the non-Alaskan conventional bottom fish processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish outside of Alaska in which the unit operations are carried out predominately through manual methods. However, the use of scaling machines and/or skinning machines are considered to be normal practice within this subcategory. The provisions of this subpart apply to the processing of currently, commercially processed species of bottom fish such as flounder, ocean perch, haddock, cod, sea catfish, sole, halibut, and rockfish. These provisions apply to existing facilities processing more than 1816 kg (4000 lbs) of raw material per day on any day during a calendar year and all new sources.
§ 408.211 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.212 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 3.6 2.0
Oil and grease............................ 1.0 0.55
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 3.6 2.0
Oil and grease............................ 1.0 0.55
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55788, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33945, June 29, 1995]
§ 408.213 [Reserved]
top
§ 408.214 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55788, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.215 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 1.2 0.71
TSS....................................... 1.5 0.73
Oil and grease............................ 0.077 0.042
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 1.2 0.71
TSS....................................... 1.5 0.73
Oil and grease............................ 0.077 0.042
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55788, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]
§ 408.216 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55788, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.217 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.212 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart V—Non-Alaskan Mechanized Bottom Fish Processing Subcategory
top
Source: 40 FR 55789, Dec. 1, 1975, unless otherwise noted.
§ 408.220 Applicability; description of the non-Alaskan mechanized bottom fish processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish outside of Alaska in which the unit operations (particularly the butchering and/or filleting operations) are carried out predominately through mechanized methods. The provisions of this subpart apply to the processing of bottom fish such as whiting and croaker.
§ 408.221 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.222 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 22 12
Oil and grease............................ 9.9 3.9
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 22 12
Oil and grease............................ 9.9 3.9
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55789, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR 33946, June 29, 1995]
§ 408.223 [Reserved]
top
§ 408.224 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55789, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.225 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 13 7.5
TSS....................................... 5.3 2.9
Oil and grease............................ 1.2 0.47
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 13 7.5
TSS....................................... 5.3 2.9
Oil and grease............................ 1.2 0.47
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55789, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]
§ 408.226 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55789, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.227 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.222 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart W—Hand-Shucked Clam Processing Subcategory
top
Source: 40 FR 55790, Dec. 1, 1975, unless otherwise noted.
§ 408.230 Applicability; description of the hand-shucked clam processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from existing hand-shucked clam processing facilities which process more than 1816 kg (4000 lbs) of raw material per day on any day during a calendar year and all new sources.
§ 408.231 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.232 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 59 18
Oil and grease............................ 0.60 0.23
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 59 18
Oil and grease............................ 0.60 0.23
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.233 [Reserved]
top
§ 408.234 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.235 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 55 17
Oil and grease............................ 0.56 0.21
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 55 17
Oil and grease............................ 0.56 0.21
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 408.236 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.237 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.232 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart X—Mechanized Clam Processing Subcategory
top
Source: 40 FR 55791, Dec. 1, 1975, unless otherwise noted.
§ 408.240 Applicability; description of the mechanized clam processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from mechanized clam processing.
§ 408.241 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.242 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
TSS....................................... 90 15
Oil and grease............................ 4.2 0.97
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
TSS....................................... 90 15
Oil and grease............................ 4.2 0.97
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.243 [Reserved]
top
§ 408.244 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.245 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
BOD5...................................... 15 5.7
TSS....................................... 26 4.4
Oil and grease............................ 0.40 0.092
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
BOD5...................................... 15 5.7
TSS....................................... 26 4.4
Oil and grease............................ 0.40 0.092
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 408.246 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]
§ 408.247 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.242 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory
top
Source: 40 FR 55792, Dec. 1, 1975, unless otherwise noted.
§ 408.250 Applicability; description of the Pacific Coast hand-shucked oyster processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from existing Pacific Coast handshucked oyster processing facilities which process more than 454 kg (1000 lbs) of product per day on any day during a calendar year and all new sources.
§ 408.251 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean the weight of the oyster meat after shucking.
§ 408.252 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-----------------------------
TSS....................................... 47 38
Oil and grease............................ 2.4 1.8
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
product)
-----------------------------
TSS....................................... 47 38
Oil and grease............................ 2.4 1.8
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55792, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR, 33946, June 29, 1995]
§ 408.253 [Reserved]
top
§ 408.254 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55792, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]
§ 408.255 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
product)
-----------------------------
TSS....................................... 45 36
Oil and grease............................ 2.2 1.7
pH........................................ (\1\) (\1\)
-----------------------------English (continued)