Loading (50 kb)...'
(continued)
[51 FR 24997, July 9, 1986]
Subpart O—Fish Meal Processing Subcategory
top
Source: 40 FR 55781, Dec. 1, 1975, unless otherwise noted.
§ 408.150 Applicability; description of the fish meal processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of menhaden on the Gulf and Atlantic Coasts and the processing of anchovy on the West Coast into fish meal, oil and solubles.
§ 408.151 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.152 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any menhaden or anchovy fish meal reduction facility which utilizes a solubles plant to process stick water or bail water shall meet the following limitations.
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 7.0 3.9
TSS....................................... 3.7 1.5
Oil and grease............................ 1.4 0.76
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 7.0 3.9
TSS....................................... 3.7 1.5
Oil and grease............................ 1.4 0.76
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any menhaden or anchovy fish meal reduction facility not covered under §408.152(a) shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units (kg/
kkg of
seafood)
-----------------------------
BOD5...................................... 3.5 2.8
TSS....................................... 2.6 1.7
Oil and grease............................ 3.2 1.4
pH........................................ (\1\) (\1\)
-----------------------------
English
units (lb/
1,000 lb
of
seafood)
-----------------------------
BOD5...................................... 3.5 2.8
TSS....................................... 2.6 1.7
Oil and grease............................ 3.2 1.4
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33943, June 29, 1995]
§ 408.153 [Reserved]
top
§ 408.154 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33943, June 29, 1995]
§ 408.155 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 6.7 3.8
TSS....................................... 3.7 1.5
Oil and grease............................ 1.4 0.76
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 6.7 3.8
TSS....................................... 3.7 1.5
Oil and grease............................ 1.4 0.76
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976]
§ 408.156 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.157 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.152 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart P—Alaskan Hand-Butchered Salmon Processing Subcategory
top
Source: 40 FR 55782, Dec. 1, 1975, unless otherwise noted.
§ 408.160 Applicability; description of the Alaskan hand-butchered salmon processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the hand-butchering of salmon in Alaska.
§ 408.161 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.162 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 2.6 1.6
Oil and grease............................ 0.31 0.19
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 2.6 1.6
Oil and grease............................ 0.31 0.19
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any hand-butchered salmon processing facility not covered under §408.162(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
[40 FR 55782, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33944, June 29, 1995]
§ 408.163 [Reserved]
top
§ 408.164 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.165 Standards of performance for new sources.
top
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(1) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 2.3 1.4
Oil and grease............................ 0.28 0.17
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 2.3 1.4
Oil and grease............................ 0.28 0.17
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(2) Any hand-butchered salmon processing facility not covered under §408.165(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
(b) [Reserved]
[40 FR 55782, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976]
§ 408.166 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.167 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.
top
(a) [Reserved]
(b) Except as provided in §§125.30 through 125.32, any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.162(b)(2) of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24998, July 9, 1986]
Subpart Q—Alaskan Mechanized Salmon Processing Subcategory
top
Source: 40 FR 55783, Dec. 1, 1975, unless otherwise noted.
§ 408.170 Applicability; description of the Alaskan mechanized salmon processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the mechanized butchering of salmon in Alaska.
§ 408.171 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.172 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 44 26
Oil and grease............................ 29 11
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 44 26
Oil and grease............................ 29 11
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any mechanized salmon processing facility not covered under §408.172(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
[40 FR 55783, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33944, June 29, 1995]
§ 408.173 [Reserved]
top
§ 408.174 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.175 Standards of performance for new sources.
top
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(1) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 42 25
Oil and grease............................ 28 10
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 42 25
Oil and grease............................ 28 10
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(2) Any mechanized salmon processing facility not covered under §408.175(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
(b) [Reserved]
[40 FR 55783, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]
§ 408.176 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.177 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.172 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart R—West Coast Hand-Butchered Salmon Processing Subcategory
top
Source: 40 FR 55784, Dec. 1, 1975, unless otherwise noted.
§ 408.180 Applicability; description of the West Coast hand-butchered salmon processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the hand-butchering of salmon on the West Coast.
§ 408.181 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.182 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 2.6 1.6
Oil and grease............................ 0.31 0.19
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 2.6 1.6
Oil and grease............................ 0.31 0.19
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55784, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33944, June 29, 1995]
§ 408.183 [Reserved]
top
§ 408.184 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55784, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]
§ 408.185 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 2.7 1.7
TSS....................................... 0.70 0.42
Oil and grease............................ 0.045 0.026
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 2.7 1.7
TSS....................................... 0.70 0.42
Oil and grease............................ 0.045 0.026
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55784, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]
§ 408.186 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.187 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.182 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart S—West Coast Mechanized Salmon Processing Subcategory
top
Source: 40 FR 55786, Dec. 1, 1975, unless otherwise noted.
§ 408.190 Applicability; description of the West Coast mechanized salmon processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the mechanized butchering of salmon on the West Coast.
§ 408.191 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.192 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
TSS....................................... 44 26
Oil and grease............................ 29 11
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
TSS....................................... 44 26
Oil and grease............................ 29 11
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55786, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33945, June 29, 1995]
§ 408.193 [Reserved]
top
§ 408.194 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55786, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.195 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
seafood)
-----------------------------
BOD5...................................... 62 38
TSS....................................... 13 7.6
Oil and grease............................ 4.2 1.5
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
seafood)
-----------------------------
BOD5...................................... 62 38
TSS....................................... 13 7.6
Oil and grease............................ 4.2 1.5
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[40 FR 55786, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]
§ 408.196 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
BOD5...................................... No limitation.
TSS....................................... Do.
pH........................................ Do.
Oil and grease............................ Do.
------------------------------------------------------------------------
[40 FR 55786, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]
§ 408.197 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.192 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24997, July 9, 1986]
Subpart T—Alaskan Bottom Fish Processing Subcategory
top
Source: 40 FR 55787, Dec. 1, 1975, unless otherwise noted.
§ 408.200 Applicability; description of the Alaskan bottom fish processing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish such as halibut in Alaska.
§ 408.201 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.
§ 408.202 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available. (continued)