CCLME.ORG - 40 CFR PART 432—MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY
Loading (50 kb)...'
(continued) rm................................ (\2\) (\3\)
O&G (as HEM).............................. 14 8.0
TSS........................................... 30 20
------------------------------------------------------------------------
\1\ mg/L (ppm).
\2\ Maximum of 400 MPN or CFU per 100 mL at any time.
\3\ No maximum monthly average limitation.


§ 432.123 Effluent limitations attainable by the application of the best available technology economically achievable (BAT).
top
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart that further processes more than 7 million pounds per year (in units of finished product) must achieve the following effluent limitations representing the application of BAT:


Effluent Limitations
[BAT]
------------------------------------------------------------------------
Maximum
Regulated parameter Maximum monthly avg.
daily \1\ \1\
------------------------------------------------------------------------
Ammonia (as N).............................. 8.0 4.0
Total Nitrogen.............................. 147 103
------------------------------------------------------------------------
\1\ mg/L (ppm).


§ 432.124 Pretreatment standards for existing sources (PSES). [Reserved]
top
§ 432.125 New source performance standards (NSPS).
top
Any source that is a new source subject to this subpart must achieve the following performance standards:

(a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:


Performance Standards
[NSPS]
------------------------------------------------------------------------
Maximum
Regulated parameter Maximum monthly avg.
daily \1\ \1\
------------------------------------------------------------------------
Ammonia (as N).............................. 8.0 4.0
BOD5........................................ 26 16
Fecal Coliform.............................. (\2\) (\3\)
O&G (as HEM)............................ 14 8.0
TSS......................................... 30 20
------------------------------------------------------------------------
\1\ mg/L (ppm).
\2\ Maximum of 400 MPN or CFU per 100 mL at any time.
\3\ No maximum monthly average limitation.


(b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:


Effluent Limitations
[NSPS]
------------------------------------------------------------------------
Maximum
Regulated parameter Maximum monthly avg.
daily \1\ \1\
------------------------------------------------------------------------
Ammonia (as N).............................. 8.0 4.0
BOD5........................................ 26 16
Fecal Coliform.............................. (\2\) (\3\)
O&G (as HEM)............................ 14 8.0
TSS......................................... 30 20
Total Nitrogen.............................. 147 103
------------------------------------------------------------------------
\1\ mg/L (ppm).
\2\ Maximum of 400 MPN or CFU per 100 mL at any time.
\3\ No maximum monthly average limitation.


§ 432.126 Pretreatment standards for new sources (PSNS). [Reserved]
top
§ 432.127 Effluent limitations attainable by the application of the best control technology for conventional pollutants (BCT).
top
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BCT: Limitations for BOD5, TSS, O&G (as HEM), and fecal coliform are the same as the corresponding limitation specified in §432.122.