Loading (50 kb)...'
(continued)
Oil and grease............................ 0.25 .07
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.09 0.02
COD....................................... 0.40 .09
TSS....................................... 0.15 .03
Surfactants............................... 0.15 .03
Oil and grease............................ 0.25 .07
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33954, June 29, 1995]
§ 417.93 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.07 0.02
COD....................................... 0.27 .09
TSS....................................... 0.09 .03
Surfactants............................... 0.09 .03
Oil and grease............................ 0.21 .07
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.07 0.02
COD....................................... 0.27 .09
TSS....................................... 0.09 .03
Surfactants............................... 0.09 .03
Oil and grease............................ 0.21 .07
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.94 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
Surfactants............................... Do.
------------------------------------------------------------------------
[40 FR 6443, Feb. 11, 1975, as amended at 60 FR 33954, June 29, 1995]
§ 417.95 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.09 .03
TSS....................................... 0.06 .02
Surfactants............................... 0.03 .01
Oil and grease............................ 0.12 .04
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.09 .03
TSS....................................... 0.06 .02
Surfactants............................... 0.03 .01
Oil and grease............................ 0.12 .04
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.96 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33954, June 29, 1995]
Subpart J—Air—SO3 Sulfation and Sulfonation Subcategory
top
§ 417.100 Applicability; description of the air—SO3 sulfation and sulfonation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the manufacture of sulfonic acids and sulfuric acid esters by means of sulfation and sulfonation employing air and sulfur trioxide (SO3), in either continuous or batch processes.
§ 417.101 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.
(c) The term surfactant shall mean those methylene blue active substances amenable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.
§ 417.102 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.15 .05
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.10 .05
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33954, June 29, 1995]
§ 417.103 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.30 0.19
COD....................................... 1.10 .55
TSS....................................... 0.04 .02
Surfactants............................... 0.36 .18
Oil and grease............................ 0.08 .04
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.30 0.19
COD....................................... 1.10 .55
TSS....................................... 0.04 .02
Surfactants............................... 0.36 .18
Oil and grease............................ 0.08 .04
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.104 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
Surfactants............................... Do.
------------------------------------------------------------------------
[40 FR 6443, Feb. 11, 1975, as amended at 60 FR 33954, June 29, 1995]
§ 417.105 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.18 0.09
COD....................................... 0.80 .40
TSS....................................... 0.04 .02
Surfactants............................... 0.18 .09
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.18 0.09
COD....................................... 0.80 .40
TSS....................................... 0.04 .02
Surfactants............................... 0.18 .09
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.106 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33954, June 29, 1995]
Subpart K—SO3 Solvent and Vacuum Sulfonation Subcategory
top
§ 417.110 Applicability; description of the SO3 solvent and vacuum sulfonation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the operations in which undiluted SO3 and organic reactant are fed through a mixing nozzle into a vacuum reactor where the sulfonation of the organic reactant takes place.
§ 417.111 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.
(c) The term surfactant shall mean those methylene blue active substances amenable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.
§ 417.112 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 3.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.10 .05
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 3.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.10 .05
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33954, June 29, 1995]
§ 417.113 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.114 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
Surfactants............................... Do.
------------------------------------------------------------------------
[40 FR 6443, Feb. 11, 1975, as amended at 60 FR 33954, June 29, 1995]
§ 417.115 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.116 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33954, June 29, 1995]
Subpart L—Sulfamic Acid Sulfation Subcategory
top
§ 417.120 Applicability; description of the sulfamic acid sulfation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from operations in which sulfamic acid is employed as the sulfating agent.
§ 417.121 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.
(c) The term surfactant shall mean those methylene blue active substances amenable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.
§ 417.122 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.15 .05
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.15 .05
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33954, June 29, 1995]
§ 417.123 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .48
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .48
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.124 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
Surfactants............................... Do.
------------------------------------------------------------------------
[40 FR 6443, Feb. 11, 1975, as amended at 60 FR 33954, June 29, 1995]
§ 417.125 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.20 0.10
COD....................................... 0.90 .45
TSS....................................... 0.02 .01
Surfactants............................... 0.20 .10
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
§ 417.126 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33954, June 29, 1995]
Subpart M—Chlorosulfonic Acid Sulfation Subcategory
top
§ 417.130 Applicability; description of the chlorosulfonic acid sulfation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from sulfation of alcohols, alkylphenols and alcohol ethoxylates utilizing chlorosulfonic acid as the sulfating agent.
§ 417.131 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.
(c) The term surfactant shall mean those methylene blue active substances amendable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.
§ 417.132 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.15 .05
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.90 0.30
COD....................................... 4.05 1.35
TSS....................................... 0.09 .03
Surfactants............................... 0.90 .30
Oil and grease............................ 0.15 .05
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33955, June 29, 1995]
§ 417.133 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.30 0.15
COD....................................... 1.50 .75
TSS....................................... 0.04 .02
Surfactants............................... 0.30 .15
Oil and grease............................ 0.06 .03
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(poundsper 1,000 (continued)