CCLME.ORG - 40 CFR PART 417—SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY
Loading (50 kb)...'
(continued)
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
------------------------------------------------------------------------


[40 FR 6442, Feb. 11, 1975, as amended at 60 FR 33952, June 29, 1995]

§ 417.45 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.80 0.40
COD....................................... 2.40 1.20
TSS....................................... 0.20 .10
Oil and grease............................ 0.08 .04
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.80 0.40
COD....................................... 2.40 1.20
TSS....................................... 0.20 .10
Oil and grease............................ 0.08 .04
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.46 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33953, June 29, 1995]

Subpart E—Glycerine Distillation Subcategory
top
§ 417.50 Applicability; description of the glycerine distillation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the production of finished glycerine of various grades (e.g., USP) through concentration from crude glycerine by means of distillation.

§ 417.51 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

§ 417.52 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 1.50 0.50
COD....................................... 4.50 1.50
TSS....................................... 0.60 .20
Oil and grease............................ 0.30 .10
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 1.50 0.50
COD....................................... 4.50 1.50
TSS....................................... 0.60 .20
Oil and grease............................ 0.30 .10
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.53 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.60 0.30
COD....................................... 1.80 .90
TSS....................................... 0.08 .04
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.60 0.30
COD....................................... 1.80 .90
TSS....................................... 0.08 .04
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.54 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
------------------------------------------------------------------------


[40 FR 6442, Feb. 11, 1975, as amended at 60 FR 33953, June 29, 1995]

§ 417.55 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.60 0.30
COD....................................... 1.80 .90
TSS....................................... 0.08 .04
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.60 0.30
COD....................................... 1.80 .90
TSS....................................... 0.08 .04
Oil and grease............................ 0.04 .02
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.56 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33953, June 29, 1995]

Subpart F—Manufacture of Soap Flakes and Powders Subcategory
top
§ 417.60 Applicability; description of the manufacture of soap flakes and powders subcategory.
top
The provisions of this subpart are applicable to discharges resulting from all operations associated with the manufacture of soap flakes and powders, commencing with the drying of the neat soap to and including packaging of the finished flakes and powders.

§ 417.61 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

(c) The term neat soap shall mean the solution of completely saponified and purified soap containing about 20–30 percent water which is ready for final formulation into a finished product.

§ 417.62 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.15 .05
TSS....................................... 0.03 .01
Oil and grease............................ 0.03 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.15 .05
TSS....................................... 0.03 .01
Oil and grease............................ 0.03 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.63 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.64 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
------------------------------------------------------------------------


[40 FR 6442, Feb. 11, 1975, as amended at 60 FR 33953, June 29, 1995]

§ 417.65 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.66 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33953, June 29, 1995]

Subpart G—Manufacture of Bar Soaps Subcategory
top
§ 417.70 Applicability; description of the manufacture of bar soaps subcategory.
top
The provisions of this subpart are applicable to discharges resulting from all operations associated with conversion of neat soap to finished bar soaps, including drying, milling, plodding, stamping and packaging.

§ 417.71 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

(c) The term neat soap shall mean the solution of completely saponified and purified soap containing about 20–30 percent water which is ready for final formulation into a finished product.

§ 417.72 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 1.02 0.34
COD....................................... 2.55 .85
TSS....................................... 1.74 .58
Oil and grease............................ 0.12 .04
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 1.02 0.34
COD....................................... 2.55 .85
TSS....................................... 1.74 .58
Oil and grease............................ 0.12 .04
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.40 0.20
COD....................................... 1.20 .60
TSS....................................... 0.68 .34
Oil and grease............................ 0.06 .03
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.40 0.20
COD....................................... 1.20 .60
TSS....................................... 0.68 .34
Oil and grease............................ 0.06 .03
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.74 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
------------------------------------------------------------------------


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.75 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.40 0.20
COD....................................... 1.20 .60
TSS....................................... 0.68 .34
Oil and grease............................ 0.06 .03
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.40 0.20
COD....................................... 1.20 .60
TSS....................................... 0.68 .34
Oil and grease............................ 0.06 .03
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.76 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33953, June 29, 1995]

Subpart H—Manufacture of Liquid Soaps Subcategory
top
§ 417.80 Applicability; description of the manufacture of liquid soaps subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the blending of ingredients employed in the manufacture of liquid soaps and the packaging of the finished products.

§ 417.81 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

§ 417.82 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.15 .05
TSS....................................... 0.03 .01
Oil and grease............................ 0.03 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.03 0.01
COD....................................... 0.15 .05
TSS....................................... 0.03 .01
Oil and grease............................ 0.03 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.83 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.84 Pretreatment standards for existing sources.
top
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.



------------------------------------------------------------------------
Pollutant or pollutant property Pretreatment standard
------------------------------------------------------------------------
pH........................................ No limitation.
BOD5...................................... Do.
TSS....................................... Do.
Oil and grease............................ Do.
COD....................................... Do.
------------------------------------------------------------------------


[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33953, June 29, 1995]

§ 417.85 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
-----------------------------
English
units
(pounds
per 1,000
lb of
anhydrous
product)
-----------------------------
BOD5...................................... 0.02 0.01
COD....................................... 0.10 .05
TSS....................................... 0.02 .01
Oil and grease............................ 0.02 .01
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.


§ 417.86 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33954, June 29, 1995]

Subpart I—Oleum Sulfonation and Sulfation Subcategory
top
§ 417.90 Applicability; description of the oleum sulfonation and sulfation subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the manufacture of sulfonic acid and sulfuric acid esters by means of sulfonation and sulfation of raw materials, including but not limited to petroleum derived alkyls, employing oleum in either continuous or batch processes.

§ 417.91 Specialized definitions.
top
For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

(c) The term surfactant shall mean those methylene blue active substances amendable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.

§ 417.92 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):



------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed_
------------------------------------------------------------------------
Metric
units
(kilograms
per 1,000
kg of
anhydrous
product)
-----------------------------
BOD5...................................... 0.09 0.02
COD....................................... 0.40 .09
TSS....................................... 0.15 .03
Surfactants............................... 0.15 .03 (continued)