Loading (50 kb)...'
(continued)
Gas Water Heaters, Circulating
Tank, Instantaneous and Large
Auto, Storage Type................... Z21.10.3-1975
Gas Heating Appliances or
Mobile Homes and Travel Trailers..... 307(b)-1965
Hotel and Restaurant Gas Ranges
and Unit Broilers.................... Z21.3-1975
[FNa1]
Hotel and Restaurant Gas Deep
Fat Fryers........................... Z21.27-1974
[FNa1]
Household Cooking Gas
Appliances........................... Z21.1-1978
Liquid Fuel-Burning Heating
Appliances For MH & TT............... 307(a)-1976
Manual Food and Beverage
Dispensing Equip..................... NSF-18-1978
Soda Fountain and Luncheonette
Equipment............................ NSF-1-1978
Vending Machines for Food and
Beverages............................ NSF-25-1978
Refrigerators Using Gas
Fuel................................. Z21.19-1975
[FNa1]
Ferrous Pipe and Fittings
Black and Hot Dipped
Zinc-Coated (Galvanized) Welded
and Seamless Steel Pipe for
Ordinary Uses........................ ASTM A120-
72a.
WW-P-406D73
Electric-Resistance Welded
Coiled Steel Tubing for Gas
and Fuel Oil Lines................... ASTM A
539-73
Type ANSI UL Other
Standards
Pipe Threads...................... B2.1-1968
Wrought-Steel and Wrought-
Iron Pipe......................... B36.10-1970
Nonferrous Pipe, Tubing and
Fittings Coated Flexible Metal
Gas Con-
nectors for Exterior Use.......... IAPMO TSC 9-72
Metal Connectors for Gas
Appliances........................ Z21.24-1973
[FNa1]
Manually Operated Gas Valves...... Z21.15-1974
[FNa1]
Seamless Copper Water Tube........ ASTM B88-72
Seamless Copper Tube for Air
Conditioning and Refrigeration
Field Service.................... ASTM B 280-73
Wrought Seamless Copper
and Copper Alloy Tube............. ASTM B251-71
Miscellaneous
Air Conditioning & Ventilating
Systems........................... NFPA 90-A-1974
Air Ducts......................... UL 181--
1974
Automatic Gas Ignition Systems
and Components.................... Z21.20-1975
Automatic Valves for Gas
Appliances........................ Z21.21-1974
[FNa1]
Gas Appliance Thermostats......... Z21.23-1975
[FNa1]
Gas Vents......................... Z131.2-1973 UL 441--
1973
Factory-Built Chimneys............ A131.1-1971 UL 103--
1971
Installation of Oil Burning
Equipment......................... Z95.1-1974 NFPA No.
31-197
Installation of Gas Appliances,
Gas Piping in Building............ NFPA No.
54-197
LPG Containers and Accessories.... ASME,DOT
Pigtails, Expansion Coils, and
Flexible Hose Connectors
for LP-Gas....................... UL 569--
1975
Quick-Disconnect Devices
for Use with Gas.................. Z21.41-1971
Resident Type Warm Air
Heating and Air Conditioning...... NFPA No. 90B73
Roof Jacks for Mobile Homes....... UL 311--
1976
Relief Valves and Automatic
Gas Shutoff Devices for
Hot Water Supply Systems.......... Z21.22-1971
[FNa1]
Storage and Handling of Liquefied
Petroleum Gas.................... Z106.1-1974 NFPA No.
58-1974
Tests for Flammability of Plastic
Materials for Parts
in Devices and Appliances......... UL94-19-
76
Tube Fittings for Flammable and
Combustible Fluids
and Refrigeration Service......... UL 109--
1978
[FNa1]
[FNa1] With Addenda.
Notes to Table
Abbreviations used in this Table refer to standards as identified below and
elsewhere in this Standard.
AGA: Standards and Tentative Standards published by the American Gas Association, Inc. Laboratories, 8501 East Pleasant Valley Rd., Cleveland, Ohio 44131.
ANSI: American National Standards Institute, 1430 Broadway, New York, New York 10017.
ASME: Standards and Tentative Standards published by the American Society of Mechanical Engineers, 345 East 47th Street, New York, New York 10017.
ASTM: Standards and Tentative Standards published by the American Society for Testing and Materials, 1961 Race Street, Philadelphia, Pennsylvania 19103.
DOT: Regulations published in the Federal Code of Regulations for the Department of Transportation. Title 49, Parts 171-190 of the FR are applicable. Available from the U.S. Government Printing Office, Washington, D.C. 20234.
GAL: Standards of Gas Appliance Laboratory, Inc., 3138 East Olympic Blvd., Los Angeles, CA 90023
IAPMO: Standards (designated above as TSC (Trailer Standard)) published by the International Association of Plumbing and Mechanical Officials, 5032 Alhambra Ave., Los Angeles, California 90032.
NFPA: Standards published by the National Fire Protection Association, 470 Atlantic Avenue, Boston, Massachusetts 02210.
NSF: National Sanitation Foundation, 3475 Plymouth Rd., P.O. Box 1468, Ann Arbor, MI 48106.
UL: Standards and Tentative Standards published by the Underwriters Laboratories Inc., 207 East Ohio St., Chicago, Illinois 60611.
WW-P: Standards published by the Federal Supply Service of the General Services Administration available from Specification Sales (3FRSBS), Bldg. 197, Washington Navy Yard, General Services Administration, Washington, D.C. 20407.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
Appendix CC-M-2
Sizing and Capacities of Gas Piping
In order to determine the size of piping to be used in designing a gas piping system, the following factors must be considered:
(1) Allowable loss in pressure from the commercial coach gas supply connection to appliance.
(2) Maximum gas consumption to be provided.
(3) Length of piping and number of fittings.
(4) Specific gravity of the gas.
(5) Diversity factor.
DESCRIPTION OF TABLES
(a) The quantity of gas to be provided at each outlet shall be determined directly from the manufacturer's Btu input rating of the appliance that will be installed.
(b) Capacities for gas at low pressures (0.5 psig or less) in thousands of BTUH of 0.60 specific gravity gas for different sizes and lengths are shown in Table CC-M-3 for iron pipe or equivalent rigid pipe and for semirigid tubing. Table CC-M-3 is based upon a pressure drop of 0.5 inch water column. In using these Tables no additional allowance is necessary for an ordinary number of fittings.
(c) Capacities in thousands of Btu per hour of undiluted liquefied petroleum gases based on a pressure drop of 0.5 inch water column for different sizes and lengths are shown in Table CC-M-3 for iron pipe or equivalent rigid pipe and for semirigid tubing. In using these Tables, no additional allowance is necessary for an ordinary number of fittings.
(d) For any gas piping system, for special gas appliances or for conditions other than those covered by Table CC-M-3 such as longer runs, greater gas demands, or greater pressure drops, the size of each gas piping system shall be determined by standard engineering methods acceptable to the department.
USE OF CAPACITY TABLES
To determine the size of each section of gas piping in a system within the range of the capacity tables, proceed as follows:
(a) Determine the gas demand of each appliance to be attached to the piping system. When Table CC-M-3 is to be used to select the piping size, calculate the gas demand in terms of thousands of BTUH for each piping system outlet.
(b) Measure the length of piping from the gas supply connection, to the most remote outlet in the commercial coach.
(c) In the appropriate capacity table, select the column showing the measured length or the next longer length if the table does not give the exact length. This is the only length used in determining the size of any section of gas piping.
(d) Use this same vertical column to locate all gas demand figures for this particular system of piping.
(e) Starting at the most remote outlet, find in the vertical column just selected the gas demand for that outlet. If the exact figure or demand is not shown, choose the next larger figure below in the column.
(f) Opposite this demand figure, in the first column at the left, will be found the correct size of gas piping.
(g) Using this same vertical column, proceed in a similar manner for each outlet and each section of gas piping. For each section of piping, determine the total gas demand supplied by that section. Where gas piping sections serve both heating and cooling equipment and the installation prevents both units from operating simultaneously, only the larger of the two demand loads need be used in sizing these sections.
EXAMPLE OF PIPING SYSTEM DESIGN:
Determine the required pipe size of each section and outlet of the piping system shown in Exhibit 1, with a designated pressure drop of 0.05 inch water column.
SOLUTION
(1) The length of pipe from the gas supply inlet to the most remote outlet (a) is 60 feet. This is the only distance used.
(2) Using the column marked 60 feet in the Table:
Outlet A, supplying 30,000 BTUH, requires 3 /8 " iron pipe.
Outlet B, supplying 3,000 BTUH, requires 1 /4 " iron pipe.
Section 1, supplying outlets A and B, or 33,000 BTUH, requires 3 /8 " iron pipe.
Outlet C, supplying 73,000 BTUH, requires 3 /4 " iron pipe
Section 2, supplying outlets A, B, and C, or 106,000 BTUH, requires 3 /4 " iron pipe.
Outlet D, supplying 136,000 BTUH requires 3 /4 inch pipe.
Section 3, supplying outlets A, B, C, and D, or 242,000 BTUH, requires 1 " iron pipe.
TABLE CC-M-3 Gas Pipe Sizing Maximum Capacity of Different Sizes of Pipe and
Tubing in Thousands of Btu's Per hour of Natural Gas For Gas Pressures of 0.5
Psig or Less and a Maximum Pressure Drop of 1 /2 Inch Water Column
[Note: The following TABLE/FORM is too wide to be displayed on one screen.
You must print it for a meaningful review of its contents. The table has been
divided into multiple pieces with each piece containing information to help you
assemble a printout of the table. The information for each piece includes: (1)
a three line message preceding the tabular data showing by line # and
character # the position of the upper left-hand corner of the piece and the
position of the piece within the entire table; and (2) a numeric scale
following the tabular data displaying the character positions.]
*******************************************************************************
******** This is piece 1. -- It begins at character 1 of table line 1. ********
*******************************************************************************
Iron Pipe Sizes
Length in Feet
I.D. 10 20 30 40 50 60 70 80 90 100 OD. 10 20 30
1/4" 43 29 24 20 18 16 15 14 13 12 3/8" 27 18 15
3/8" 95 65 52 45 40 36 33 31 29 27 1/2" 56 38 31
1/2" 175 120 97 82 73 66 61 57 53 50 5/8" 113 78 62
3/4" 360 250 200 170 151 138 125 118 110 103 3/4" 197 136 109
1" 680 465 375 320 285 260 240 220 215 195 7/8" 280 193 155
1...+...10....+...20....+...30....+...40....+...50....+...60....+...70....+....
*******************************************************************************
******* This is piece 2. -- It begins at character 80 of table line 1. ********
*******************************************************************************
Tubing
Length in Feet
40 50 60 70 80 90 100
13 11 10 9 9 8 8
26 23 21 19 18 17 16
53 47 43 39 37 34 33
93 83 75 69 64 60 57
132 117 106 98 91 85 81
80..+...90....+....0....+...10....+..
Part II Maximum Capacity of Different Sizes of Pipe and Tubing in Thousands of
Btu's Per Hour of Undiluted Liquefied Petroleum Gas Based on a Maximum Pressure
Drop of 1 /2 Inch Water Column
[Note: The following TABLE/FORM is too wide to be displayed on one screen.
You must print it for a meaningful review of its contents. The table has been
divided into multiple pieces with each piece containing information to help you
assemble a printout of the table. The information for each piece includes: (1)
a three line message preceding the tabular data showing by line # and
character # the position of the upper left-hand corner of the piece and the
position of the piece within the entire table; and (2) a numeric scale
following the tabular data displaying the character positions.]
*******************************************************************************
******** This is piece 1. -- It begins at character 1 of table line 1. ********
*******************************************************************************
Iron Pipe
Length in Feet
I.D. 10 20 30 40 50 60 70 80 90 100 O.D. 10 20 30
1/4" 67 46 37 31 28 25 23 21 20 19 3/8" 39 26 21
3/8" 147 101 81 70 62 56 51 48 45 42 1/2" 92 62 50
1/2" 275 189 152 129 114 103 96 89 83 78 5/8" 199 131 107
3/4" 567 393 315 267 237 217 196 185 173 162 3/4" 329 216 181
1" 1071 732 590 504 448 409 378 346 322 307 7/8" 501 346 277
1...+...10....+...20....+...30....+...40....+...50....+...60....+...70....+....
*******************************************************************************
******* This is piece 2. -- It begins at character 80 of table line 1. ********
*******************************************************************************
Tubing
Length in Feet
40 50 60 70 80 90 100
19
41 37 35 31 29 27 26
90 79 72 67 62 59 55
145 131 121 112 104 95 90
233 198 187 164 155 146 138
80..+...90....+....0....+...10....+...2
TABLE CC-M-4 Minimum Metal Thickness for Ducts [FNa1]
Diameter or Width
14 inches Over
Duct Type or less 14 inches
Round................... 0.013 in. 0.016 in.
Enclosed Rectangular.... 0.013 in. 0.016 in.
Exposed Rectangular..... 0.016 in. 0.019 in.
[FNa1] When "nominal" thicknesses are specified, 0.003 inch shall be added to these "minimum" metal thicknesses.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4514. Application and Scope.
The provisions of this article relating to plumbing equipment and installations apply to all commercial coaches manufactured after November 23, 1970, and sold, offered for sale, rented, or leased within this State. The provisions of this article are also applicable to the alteration or conversion of plumbing equipment and installations in any commercial coach bearing or required to bear a department insignia of approval.
(a) Standards for Equipment and Installations. Standards for equipment and installations are listed in Appendix CC-P. Equipment and installations conforming to these standards or to other standards approved by the department shall be considered acceptable when listed or labeled and installed in accordance with the requirements of this article and the conditions of their approval except where otherwise provided in this article.
(b) Plumbing Standards. Plumbing fixtures, equipment, and installations in or on a commercial coach shall conform to the applicable requirements of the Uniform Plumbing Code, 1979 edition, as published by the International Association of Plumbing and Mechanical Officials, except as otherwise provided by this article.
(c) The following provisions of the Uniform Plumbing Code, 1976 edition, are not adopted: Part 1, Chapter 1, Sections 102(f)(g), 103(k)(l) (m)(n), 104(a)(c), 105(a)(e)(f), 106(b), 109(d)(e), 113(a)(c)(d)(f), 114 (b)(d)(e), 117(b)(e)(i)(j)(l), 120(a)(b)(c)(e)(f), 124(d)(e)(f), 201, 301, 302, 303, 304, 305, 306, 307, 313, 314, 317, 319, 320, 321, 322, 401, 503, 506, 701, 704, 705, 910, 1001, 1004, Chapters 11, 12 and 13, Appendices D, E, G, and I.
Note: Authority cited: Sections 18020 and 18055, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4515. Definitions.
Definitions contained in the Health and Safety Code, Division 13, Part 2, (commencing with Section 18000) and the following definitions shall apply to this Article.
Body Waste. The discharge from any fixtures, appliance or appurtenance containing fecal matter or urine.
CPVC. Chlorinated Polyvinyl chloride.
Drain. Any pipe which carries waste or waterborn wastes in a vehicle drainage system.
Drain Outlet. The discharge end of the vehicle main drain.
Drainage System. Includes all the piping within or attached to the structure which conveys sewage or other liquid wastes to the drain outlet(s).
Main Drain. The principal artery of the vehicle drainage system to which drainage branches may be connected.
PB. Polybutylene.
Toilet -Mechanical Seal. A toilet designed with a water flushing device and mechanical sealed trap.
Toilet -Recirculating Chemical. A self-contained toilet in which waste is recirculated and chemically treated.
Uniform Plumbing Code -UPC. The 1979 edition as published by the International Association of Plumbing and Mechanical Officials.
Waste Holding Tank. A liquid tight tank for the temporary retention of body and/or liquid waste.
Water Distribution System. The potable water piping within or attached to the vehicle.
Water Supply Connection. The fitting or point of connection in the vehicle water distribution system designed for connection to a water supply.
Water Storage Tank. A tank designed for the purpose of storing potable water.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4516. Drainage Systems.
The drainage system shall be designed to provide an adequate circulation of air in all piping without danger of siphonage, aspiration or forcing of trap seals under condition of ordinary use.
(a) Materials. Drainage pipe shall be cast iron, galvanized steel, galvanized wrought iron, lead, brass, copper tube DWV, ABS plastic or other listed materials.
(b) Fittings. Drainage fittings shall be cast iron, malleable iron, lead, brass, copper DWV, ABS plastic or other listed materials having a recessed drainage pattern with smooth interior waterways of the same diameter as the piping and of a material conforming to the type of piping used.
Note: ABS drainage pipe and fittings shall only be used in vehicles with plumbing fixtures designed for domestic sewage.
(c) Drain Outlets.
(a) Except as provided in this article, each vehicle equipped with plumbing fixtures or equipment shall have at least one drain outlet which shall terminate within 18 inches of the outside wall of the vehicle.
(d) Cap or Plug. Drain outlets shall be equipped with a watertight cap or plug which shall be permanently attached to the vehicle.
(e) Clearance from Drain Outlet. The drain outlet and couplers shall be provided with a minimum clearance of three inches in any direction from all parts of the structure or appurtenances and with not less than 18 inches unrestricted clearance directly in front of the drain outlet.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4516.5. Vents and Venting.
(a) Materials. Vent pipe shall be cast iron, galvanized steel, galvanized wrought iron, lead, copper DWV, brass, ABS plastic, or other listed materials.
(b) Fittings. Vent fittings shall be cast iron, galvanized malleable iron or galvanized steel, lead, copper DWV, brass, ABS plastic, or other listed materials.
(c) Changes in direction of vent piping shall be made by the appropriate use of approved fittings and no such pipe shall be strained or bent. Burred ends shall be reamed to the full bore of the pipe.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4517. Traps Required.
(a) Except as otherwise provided in these regulations, each plumbing fixture, excepting those having integral traps, shall be separately trapped by an approved type water seal trap.
(b) It is provided, however, that one (1) trap may serve a set of not more than three (3) single compartment sinks or laundry tubs of the same depth or three (3) lavatories immediately adjacent to each other and in the same room, if the waste outlets are not more than thirty (30) inches apart and the trap is centrally located when three (3) compartments are installed. The depth requirement may be waived in the case of approved type pump discharged fixtures or appliances.
(c) No food waste disposal unit shall be installed with any set of restaurant, commercial or industrial sinks served by a single trap; each such food waste disposal unit shall be connected to a separate trap. Each domestic clothes-washer and each laundry tub shall be connected to a separate and independent trap; except that a trap serving a laundry tub may also receive the waste from a clotheswasher set adjacent thereto. No clotheswasher or laundry tub shall be connected to any trap for a kitchen sink.
(d) The vertical distance between a fixture outlet and the trap weir shall be as short as practicable, but in no case shall the tail piece from any fixture exceed twenty-four (24) inches in length.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4517.3. Traps Prohibited.
A trap that depends on concealed interior partitions for its seal, full .S' traps, bell traps, and crown-vented traps are prohibited. No fixture shall be double trapped. Drum traps may be installed only when approved by the department for special conditions. No drum trap shall be installed without a vent.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4517.5. Trap Seals.
Each .P' trap shall have a water seal of not less than two (2) inches and not more than four (4) inches, except where a deeper seal is necessary for special conditions. Traps shall be set true with respect to their water seals and where necessary they shall be protected from freezing.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4517.7. Plumbing Fixtures.
Plumbing fixtures shall have smooth impervious surfaces, be free from defects and concealed fouling surfaces, capable of resisting road shock and vibration and shall conform to nationally recognized applicable standards or other approved standards.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4517.8. Waste Holding Tanks.
Waste holding tanks installed in plumbing systems shall comply with the following:
(a) Tanks shall be listed to approved standards and securely installed in a location to be removable for service, repair or replacement without the necessity of removing permanent, structural, mechanical or electrical equipment.
(b) Minimum size of inlet connections shall be determined by the total number of fixtures to be connected to the tank.
Toilet connections shall be 3-inch minimum pipe size and shall extend vertically. The inlet fitting shall not extend downward into the tank more than 1 1/2 inches (38 mm). The toilet connection shall be designed to receive or conform to an approved shape closet flange of standard dimensions or other approved fitting.
(c) Body waste holding tank drain opening shall be a minimum 3-inch pipe size. Liquid waste holding tank drain opening shall be a minimum 1 1/2 inch pipe size. Drain openings shall be located at the lowest point in the tank.
A listed fullway valve shall be directly connected to the tank or installed in the drain pipe of the tank within 36 inches (915 mm) of the drain outlet.
(d) The tank shall be vented at the highest point in the top of the tank by one of the following methods:
(1) A 1 1/4 inch minimum diameter individual vent pipe extending undiminished in size through the roof.
(2) A wet vent serving as a drain provided the drain portion is increased one pipe size larger than the connected trap arm.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4518. Water Distribution System.
Piping systems shall be sized to provide an adequate quantity of water to each plumbing fixture at a flow rate sufficient to keep the fixture in a clean and sanitary condition without any danger of backflow or siphonage.
(a) Materials. Water pipe and fittings shall be of brass, copper, cast iron, galvanized malleable iron, galvanized wrought iron, galvanized steel, chlorinated polyvinyl chloride, polybutylene or other material listed for hot and cold water distribution systems.
(b) Used Material. Piping and tubing which has previously been used for any purpose other than for potable water systems shall not be used.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4519. Water Supply Connections.
(a) Each commercial coach equipped with a water distribution system designed for connection to an outside source shall have a water-supply connection which shall terminate within 18 inches of the outside wall of the vehicle.
(b) Cap or Plug. Water-supply connections shall be equipped with a watertight cap or plug which shall be permanently attached to the vehicle.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4522. Potable Water Storage Tanks.
Potable water storage tanks installed in plumbing systems shall comply with the following:
(a) Tanks shall be listed to approved standards and installed in a location to be removable for service, repair or replacement without the necessity of removing permanent structural, mechanical or electrical equipment. Where the tank is installed in such a manner that it may be subject to road damage it shall be provided with mechanical protection.
(b) Non-pressure gravity tanks shall be equipped with a vent at the top of the tank. Vents and overflow pipe openings shall be protected from the entrance of dirt, insects and other contamination.
(c) Potable water storage tanks designed to be pressurized, shall be equipped with a listed air pressure relief valve set to open at not more than 125 psig (862 KPA) or in accordance with the tank manufacturer's instructions.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
Appendix CC-P-1
Wall Surfacing for Tub and Shower Enclosures
I. Material: The wall covering material must have an exposed surface that
is impervious to water; the substrate material must be
resistant to deterioration from exposure to high humidity
and temporary water leakage.
A. Strength: The complete wall assembly, including the wall covering
substrate, shall be capable of withstanding a uniform load
of five pounds per square foot applied perpendicular to the
surface. The deflection, under load, shall not exceed 1
/180 of the wall, for the assembly; or 1 /240 the distance
between framing members, for the wall covering substrate.
B. Surface The exposed surface must meet the minimum requirements of the
Finish: American Hardboard Association PS59-73, Prefinished
Hardboard Paneling, Class 1, as certified by the panel
manufacturer.
C. Size: The minimum thickness of the material shall be 1 /8 "
nominal. The width to be sufficient to give continuous
unbroken surface from corner to corner, or end of tub in
corner installation, in an installation incorporating a
shower, the unbroken surface must continue to a height of
at least 6 ' above the floor of the shower.
D. Type: The substrate material shall alsomeet the requirements of the
appropriate standard listed below:
(1) Hardboard: of high strength and water resistance to meet
Commercial Standard CS-251-63, or AHA PS 58-73, either
standard or tempered.
(2) Softwood Plywood: must meet U.S. Product Standard P.S.
1-66 including exterior type glue line and grade A face
veneer "suitable for painting."
(3) Hardwood Plywood: must meet CA-35-61 Type II glue line
and sound grade face veneer.
(4) Other Materials: not meeting D-1, D-2, D-3 above, shall
meet the requirements of this code and their appropriate
Product Standard, Industry Standard, Commercial Standard,
of Federal Specification.
II. Installati- The material must be installed in conformance with this code
on: and the application instructions provided by the material
manufacturer. In case of conflict, this regulation shall
take precedence.
A. Framing: Wood framing shall be spaced not more than 16 " o.c. Blocking
shall be 1 " x 3 " or equal, installed horizontally at
height to match rim of the tub or shower pan. All corners
shall have sufficient framing members for attachment of
corner moldings.
B. Fastening: All edges and ends of panel shall occur on framing members.
Panels shall be applied to wood framing members using water
resistant, non-hard setting adhesive. Adhesive shall be
applied to the face of all framing members except locations
where panel edges fall beneath applied moldings. Panels may
also be applied over solid backing using an adhesive.
Note: Fasteners, if necessary, shall be used only in
locations where they will be covered by applied moldings,
and shall be used on not more than two adjacent edges. No
other interior fasteners, or fixtures, other than required
functional plumbing fixtures shall penetrate the face of
the panel. Openings for these plumbing fixtures must be
sealed with caulk.
C. Corners and
Edges: All corners and edges must be caulked or sealed against
moisture penetration. A non-hard setting sealant material
must be used with applied moldings. Fastening of moldings
to framing shall not be greater than 6 " o.c.
Appendix CC-P-2
Plumbing Material Standards
Other
Materials ANSI ASTM FS Standards
Ferrous Pipe Fittings
Cast-Iron Screwed Fittings............ B16.4
-1971
Malleable Iron Screwed Fittings....... B16.3
-1971
Special Cast-Iron Fittings....................................... IAPMO-PS
5-66
Welded Wrought Iron Pipe.............. B36.2 A72
-1969 -1968
Wrought-Steel and Wrought-
Iron Pipe............................. B36.10
-1970
Black and Hot Dipped Zinc-Coated
(Galvanized) Welded and Seamless
Steel Pipe............................ A120
-1972a
Welded and Seamless Steel Pipe........ B125.1 A53
-1972 -1972a
Pipe Threads (Except Dry-Seal)........ B2.
-1968
Cast-Iron Soil Piping and Fittings.... A12.5. A74 WW-P
-1971 -72 401D-1969
Nonferrous Pipe and Fittings
Seamless Copper, Pipe,
Standard Sizes........................ H26.1 B42
-1973 -1972
Wrought Seamless Copper and
Copper Alloy Tube..................... H23.4 B251
-1973 -1971
Seamless Copper Water Tube............ H23.1 B88
-1973 -1972
Copper Drainage Tube (DWV)............ H23.6 B306
-1973 -1973
Wrought Copper & Bronze
Solder-Joint Pressure Fittings........ B16.22
-1973
Wrought Copper and Wrought
Copper Alloy Solder-Joint
Drainage Fittings..................... B16.29
-1966
Cast Brass Solder-Joint Pressure
Fittings.............................. B16.18
-1972
Cast Brass Solder-Joint Drainage
Fittings-DWV.......................... B16.23
-1969
Cast Bronze Fittings for Flared
Copper Tubes.......................... B16.26
-1967
Seamless Red Brass Pipe,
Standard Sizes........................ H27.1 B43
-1973 -1972
Other
Materials ANSI ASTM FS Standard
Cast Bronze Threaded Fittings,
150 and 300 Lb....................... B16.15
-1971
Plastic Pipe and Fittings ABS Plastic
Drain, Waste, and Vent Pipe and
Fittings............................ D2661 L-P322B IAPMO-PS
-1973 -1973 PS 17-71
NSF 14 1970
PVC Plastic Drain, Waste and
Vent Pipe and Fittings.............. D2665 L-P320B IAPMO-PS
-1973 320B 27-69
-1973 NSF 14 1970
Chlorinated Poly (Vinyl/ Chloride)
(CPVC) Plastic Hot Water
Distribution Systems................ D2846 NSF 14
-1973 1970
Polybutylene (PB) Plastic Pipe
(SDR-PR)............................ D2662
-1973
Polybutylene (PB) Plastic Hot
Water Distribution................... D3309
-1974
Miscellaneous Pipe Nipples,
Threaded............................ WW-N
351B(1)
-1970
Rubber Gaskets for Cast Iron Soil
Pipe Fittings....................... C564
-1970
Backflow Prevention Devices.......... IAPMO -PS
31-71
Valve, Bronze, Gate 125-150
and 200 Pound....................... WW-V
154D 73
Valve, Cast-Iron Gate, Threaded
and Flanged......................... WW-V
58B 71
Plumbing -Fixture Setting
Compound............................ HH-C
536A'54
Cast Brass and Tubing P-Traps........ IAPMO-PS
2-66
Relief Valves and Automatic Gas
Shutoff Devices for Hot Water
Supply Systems...................... Z21.22
[FN-
a1]
-1971
Solvent Cement for ABS Plastic
Pipe and Fittings................... D2235 NSF-14
-1973 1970
Solvent Cements for PVC Plastic
Pipe and Fittings................... D2564 NSF-14
-1973a 1970
Anti-Siphon Trap Vent Device......... NSP-24
1972
Diversion Tees and Twin Waste
Elbow............................... IAPMO-PS
9-66
Flexible Copper Water Connectors..... IAPMO-PS
14-71
Dishwasher Drain Airgaps............. IAPMO-PS
23-68
Coated Flexible Metal Gas
Connectors for Exterior Use......... IAPMO
TSC 9-72
Plumbing Fixtures Plumbing
Fixtures for Land Use............... WW-P
541D-'71
Vitreous China Plumbing Fixtures..... A112.- NSF-24
19.2
-1973 -70
Enameled Cast-Iron Plumbing.......... A112.-
19.1
-1973
Porcelain Enameled Formed Steel
Plumbing Fixtures................... IAPMO
TSC22-72
Formed Metal Porcelain Enameled
Sanitaryware........................ IAPMO PS
5-67
Gel-Coated Glass-Fiber Rein-
forced Polyester Resin Bathtub
Units................................ Z124.1 NSF-24
-1967 -72
Other
Materials ANSI ASTM FS Standard
Gel-Coated Glass-Fiber Rein-
forced Polyester Resin Shower
Receptor and Shower Stall Units.... Z124.2 NSF-24
-1967 -72
Drains for Prefabricated and
Precast Showers.................... IAPMO
PS 4-66
NSF-24-72
Cultured Marble Lavatory............ IAPMO
PS 18-72
Prefabricated Shower Receptors,
Shower Enclosures
and Non-Metallic Bathtubs.......... IAPMO
PS 11-72
NSF-24-72
Performance Specifications and
Methods of Test for Safety Glazing
Material Used in Buildings......... Z97.1
-1972
[FNa1] With Addenda
Notes to Table.
Abbreviations used in Table refer to standards as identified below and elsewhere in this standard.
ANSI: American National Standards Institute, 1430 Broadway, New York, N.Y. 10017.
ASTM: Standards and Tentative Standards published by the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.
FS: Federal Specifications published by the Federal Supply Service of the General Services Administration available from Specification Sales (3FRSBS), Bldg. 197, Washington Navy Yard, General Services Administration, Washington, D.C. 20407.
IAPMO: Standards and Tentative Standards designated as UPC-PS (Uniform Plumbing Code -Product Standard) and TSC (Trailer Standard) available from the International Association of Plumbing and Mechanical Officials, 5032 Alhambra Ave., Los Angeles, CA 90032.
NSF: Standards published by the National Sanitation Foundation, NSF Building, 3475 Plymouth Road, Ann Arbor, Michigan 48105.
PS: Product Standards available from Superintendent of Documents, Government Printing Office, Washington, D.C. 20402.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4525. Application and Scope.
(a) The provisions of this article relating to construction and fire safety apply to all special purpose commercial coaches, manufactured after September 1, 1979, which are sold or offered for sale, rented or leased within this state.
(b) The provisions of this article relating to construction and fire safety apply to the alteration or conversion of any construction or fire safety equipment or installations in any special purpose commercial coach bearing or required to bear a department insignia of approval.
(c) The provisions of this article relating to construction and fire safety apply to the alteration, conversion, addition or change in occupancy of any construction and fire safety equipment or installations of any special purpose commercial coach as defined in this article.
(d) In addition to the provisions of this article, the provisions of the California Administrative Code, Title 17, Chapter 5, Subchapter 2, Group 1, Article 10, apply to Mobile Food Preparation Units.
Where a person proposes to sell, offer for sale, rent or lease a special purpose commercial coach designed as a mobile food preparation unit, manufactured after the effective date of this article, or where a department insignia of approval has not been issued, it will be necessary that such person obtain written certification from the appropriate local Health Department or State Department of Health, indicating that the special purpose commercial coach complies with the applicable provisions of the California Administrative Code, Title 17, Subchapter 2, Group 1, Article 10 relating to mobile food preparation units.
Note: Authority cited: Section 18020, Health and Safety Code. Reference: Section 18055, Health and Safety Code.
s 4526. Definitions.
s 4527. Fire Safety.
Multipurpose passenger vehicles, are subject to Federal Standards under the National Traffic and Motor Vehicle Safety Act of 1966 are exempt from the requirements of these regulations relating to interior finish flame spread limitations.
s 4528. Exits.
(a) Each special purpose commercial coach shall have a minimum of two exits located remote from each other and so arranged as to provide a means of unobstructed travel to the outside of the vehicle.
(b) The alternate means of egress shall be located in the side opposite the main exit door, or the roof, or the rear of the vehicle, with unobstructed passage of 24 " x 24 " (61 cm x 61 cm) minimum opening to the outside.
(c) The bottom of the alternate means of egress shall not be more than four (4) feet above the vehicle floor or above a readily accessible horizontal surface capable of supporting a weight of 300 pounds.
(d) The latch mechanism of any exit facility shall be operable by hand, and shall not require the use of a key or special tool or key for operation from the inside.
(e) Alternate exits, other than standard doors, shall be labeled with the word "EXIT" with 1 " (2.54 cm) minimum letters on a contrasting background.
s 4529. Ceiling Height.
Each special purpose vehicle shall have a minimum ceiling height of 74 inches.
s 4530. Room Dimensions and Construction.
(a) There shall be a clear, unobstructed height over the aisle-way portion of the unit of at least 74 inches (188 cm) from floor to ceiling, and a minimum of 30 inches (76 cm) of unobstructed horizontal aisle space.
(b) Floors, walls, and ceiling of mobile food preparation units shall be constructed so that the surfaces are durable, impervious, smooth and easily cleanable. The juncture of the floors and walls shall be covered with the floor surface extending up the wall at least 4 inches (10 cm).
(c) Construction joints and seams of mobile food preparation units shall be sealed to provide durable, smooth and easily cleanable surfaces. Soldered joints and seams shall be smooth to the touch. Silicone sealant or equivalent waterproof compounds shall be acceptable for sealing narrow seams or crevices which are 1 /8 inch (3 mm) or less in width, providing they are properly applied and they prevent the entrance of liquid or vermin.
s 4531. Glass and Glazed Openings.
The provisions of Article 3, Division 1, Section 4371 shall apply to glass and glazing in all special purpose vehicles.
s 4532. Electrical.
The provisions of Article 3, Division 2, of this subchapter, and the following shall apply to electrical equipment and installations of all special purpose commercial coaches.
(a) All 115-220 volt electrical wiring in mobile food preparation units shall be installed in listed electrical conduit.
(b) All ceiling light fixtures in mobile food preparation units shall be recessed or flush mounted and sealed and have approved safety covers. The minimum clearance from the floor to the light fixture shall be at least 74 inches (188 cm) or the fixture shall be installed out of the traffic aisle or work area.
s 4533. Mechanical.
The provisions of Article 3, Division 3, of this subchapter, shall apply to mechanical equipment and installations of all special purpose commercial coaches.
s 4534. Plumbing.
The provisions of Article 3, Division 4, and the following shall apply to plumbing equipment and installations of all special purpose commercial coaches:
(a) At least a two-compartment metal sink equipped with hot and cold running water with dual integral metal drainboards, installed with at least 1:100 slope toward the sink, and fabricated with a minimum 1 /2 inch (12.7 mm) lip or rim to prevent the draining liquid from spilling onto the floor shall be provided in each mobile food preparation unit. The dimensions of each compartment shall be at least 12 inches (30.5 cm) wide, 30.5 cm (12 inches) long, and 9 inches (22.9 cm) deep. Each drainboard shall be at least the size of the adjacent sink compartments.
If multi-use eating and drinking utensils are used, the sink shall have three compartments.
The sink shall be equipped with a mixing faucet and shall be provided with a swivel spigot capable of servicing any sink compartment.
(b) Hand washing facilities, including a lavatory supplied with hot and cold running water with a mixing type faucet, hand washing cleanser and single-service towels in permanently installed dispensers shall be provided and maintained in each mobile food preparation unit. The lavatory basin shall have a minimum dimensions of 9 " x 9 " or (22.9 cm x 22.9 cm) and 5 " (12.7 cm) in depth. The hand washing facilities shall be separated from the utensil washing sinks by a metal guard, with a height of at least 3 " (76 mm) extending from the back edge of the drainboard to the front edge of the drainboard. The corners of the barrier shall be rounded. No separation barrier is required if the distance between the hand washing sink and the utensil drainboards is at least 2 ' (61 cm).
(c) An adequate quantity of potable water for food preparation, cleaning and handwashing purposes shall be provided in all mobile food preparation units by either an approved self-contained water supply tank having a minimum capacity of 30 gallons (114 liters) or an approved water system hook-up. Hose connection valves shall be at least 5 ' (1.5 meters) above the ground and be kept covered with a protective screw-type cap which is attached to the vehicle. The hose connection shall consist of a quick-disconnect device which is compatible with a complementary device installed on the potable water hose(s) at the point of supply.
The water system shall be of such materials and designed and constructed so water or air can be introduced without the water becoming contaminated. The water system shall deliver at least one gallon (4 liters) per minute to each sink basin in the unit.
(d) A water heater with a minimum capacity of 3 gallons (11 liters) or an instantaneous heater capable of producing water of 120 degrees Fahrenheit (49 celsius) interconnected with the potable water supply, shall be provided in all mobile food preparation units and shall operate independently of the vehicle engine and/or generator. Hot and cold water, under pressure, shall be provided at hand washing and utensil sinks from mixing faucets.
(e) All liquid (including melting ice water) waste systems in mobile food preparation units shall be connected to an approved liquid waste tank with a minimum capacity of 45 gallons (170 liters) or shall be designed to be connected to a sewage disposal system.
(f) All tanks, lines, couplings, valves, or any other plumbing in mobile food preparation units shall be designed, installed, maintained, and constructed of materials that will not contaminate the water supply, food, utensils, or equipment.
(g) Water and waste storage tanks in mobile food preparation units shall be installed so as to be easily drained, flushed, and cleaned with an easily accessible outlet. Breather tubes or overflow pipe openings shall be protected from the entrance of dust, insects, and other contamination. All waste lines shall be connected to the waste tank with watertight seals.
s 4535. Ventilation.
Mechanical exhaust ventilation equipment shall be provided over all cooking equipment to remove cooking odors, smoke, steam, grease and vapors. The ventilation shall be adequateto provide a reasonable condition of comfort for employees. Grease filters or other means of grease extraction are required and shall be of steel construction, or other approved material, and shall be readily accessible for cleaning. Every joint and seam shall be substantially tight. No solder shall be used, except for sealing a joint or seam. Every hood shall be so designed and installed to provide for thorough cleaning of the entire hood. When grease gutters are provided they shall drain to a collecting receptacle fabricated, designed, and installed to be readily accessible for cleaning. All ducts in the exhaust system shall have a slope of at least 1:6. All seams in this duct work shall be substantially tight to prevent the accumulation of grease. The ducts shall have sufficient clean-outs to make them readily accessible for cleaning. Make-up air shall be provided at the rate of that exhausted. It may be accomplished from screened service openings, screened vents in the ceiling, or mechanically through an air-conditioning system, but not through open doors or openable windows. (continued)