In a fluorescent ELISA technique (such as the one employed in the Pharmacia Delphia test for B2M), the labeled enzyme is bound to a strong fluorescent dye. In the Pharmacia Delphia test, an antigen bound to a fluorescent dye competes with unlabeled antigen in the sample for a predetermined amount of specific, immobile antibody. Once equilibrium is reached, the immobile phase is removed from the labeled antigen in the sample solution and washed; an enhancement solution then is added that liberates the fluorescent dye from the bound antigen-antibody complex. The enhancement solution also contains a chelate that complexes with the fluorescent dye in solution; this complex increases the fluorescent properties of the dye so that it is easier to detect.
To determine the quantity of B2M in a sample using the Pharmacia Delphia test, the intensity of the fluorescence of the enhancement solution is measured. This intensity is proportional to the concentration of labeled antigen that bound to the immobile antibody phase during the initial competition with unlabeled antigen from the sample. Consequently, the intensity of the fluorescence is an inverse function of the concentration of antigen (B2M) in the original sample. The relationship between the fluorescence level and the B2M concentration in the sample is determined using a series of graded standards, and extrapolating these standards to find the concentration of the unknown sample.
5.3.3 Methods Developed for B2MU Determinations
B2MU usually is measured by radioimmunoassay (RIA) or enzyme-linked immunosorbent assay (ELISA); however, other methods (including gel electrophoresis, radial immunodiffusion, and nephelometric assays) also have been described (Schardun and van Epps 1987). RIA and ELISA methods are preferred because they are sensitive at concentrations as low as micrograms per liter, require no concentration processes, are highly reliable and use only a small sample volume.
Based on a survey of the literature, the ELISA technique is recommended for monitoring B2MU. While RIAs provide greater sensitivity (typically about 1 m g/l, Evrin et al. 1971), they depend on the use of radioisotopes; use of radioisotopes requires adherence to rules and regulations established by the Atomic Energy Commission, and necessitates an expensive radioactivity counter for testing. Radioisotopes also have a relatively short half-life, which corresponds to a reduced shelf life, thereby increasing the cost and complexity of testing. In contrast, ELISA testing can be performed on routine laboratory spectrophotometers, do not necessitate adherence to additional rules and regulations governing the handling of radioactive substances, and the test kits have long shelf lives. Further, the range of sensitivity commonly achieved by the recommended ELISA test (i.e., the Pharmacia Delphia test) is approximately 100 m g/l (Pharmacia 1990), which is sufficient for monitoring B2MU levels resulting from cadmium exposure. Based on the studies listed in Table 7 (Section 5.3.7), the average range of B2M concentrations among the general, nonexposed population falls between 60 and 300 m g/g CRTU. The upper 95th percentile of distributions, derived from studies in Table 9 which reported standard deviations, range between 180 and 1,140 m g/g CRTU. Also, the Pharmacia Delphia test currently is the most widely used test for assessing B2MU.
5.3.4 Sample Collection and Handling
As with CDB or CDU, sample collection procedures are addressed primarily to identify ways to minimize the degree of variability introduced by sample collection during medical monitoring. It is unclear the extent to which sample collection contributes to B2MU variability. Sources of variation include time-of-day effects, the interval since consuming liquids and the quantity of liquids consumed, and the introduction of external contamination during the collection process. A special problem unique to B2M sampling is the sensitivity of this protein to degradation under acid conditions commonly found in the bladder. To minimize this problem, strict adherence to a sampling protocol is recommended. The protocol should include provisions for normalizing the conditions under which the urine is collected. Clearly, it is important to minimize the interval urine spends in the bladder. It also is recommended that every effort be made to collect samples during the same time of day.
Collection of urine samples for biological monitoring usually is performed using "spot" (i.e., single-void) urine. Logistics and sample integrity become problems when efforts are made to collect urine over extended periods (e.g., 24 hrs). Unless single-void urines are used, numerous opportunities exist for measurement error because of poor control over sample collection, storage and environmental contamination.
To minimize the interval that sample urine resides in the bladder, the following adaption to the "spot" collection procedure is recommended: The bladder should be emptied and then a large glass of water should be consumed; the sample then should be collected within an hour after the the water is consumed.
5.3.5 Best Achievable Performance
The best achievable performance is assumed to be equivalent to the performance reported by the manufacturers of the Pharmacia Delphia test kits (Pharmacia 1990). According to the insert that comes with these kits, QC results should be within + 2 SDs of the mean for each control sample tested; a CV of less than or equal to 5.2% should be maintained. The total CV reported for test kits is less than or equal to 7.2%.
5.3.6 General Method Performance
Unlike analyses for CDB and CDU, the Pharmacia Delphia test is standardized in a commercial kit that controls for many sources of variation. In the absence of data to the contrary, it is assumed that the achievable performance reported by the manufacturer of this test kit will serve as an achievable performance objective. The CTQ proficiency testing program for B2MU analysis is expected to use the performance parameters defined by the test kit manufacturer as the basis of the B2MU proficiency testing program.
Note that results reported for the test kit are expressed in terms of m g B2M/l of urine, and have not been adjusted for creatinine. The indicated performance, therefore, is a measure of the performance of the B2M portion of the analyses only, and does not include variation that may have been introduced during the analysis of creatinine.
5.3.7 Observed B2MU Concentrations
As indicated in Section 4.3, the concentration of B2MU may serve as an early indicator of the onset of kidney damage associated with cadmium exposure.
5.3.7.1 Range of B2MU concentrations among unexposed samples
Most of the studies listed in Table 9 report B2MU levels for those who were not occupationally exposed to cadmium. Studies noted in the second column of this table (which contain the footnote "d") reported B2MU concentrations among cadmium-exposed workers who, nonetheless, showed no signs of proteinuria. These latter studies are included in this table because, as indicated in Section 4.3, monitoring B2MU is intended to provide advanced warning of the onset of kidney dysfunction associated with cadmium exposure, rather than to distinguish relative exposure. This table, therefore, indicates the range of B2MU levels observed among those who had no symptoms of renal dysfunction (including workers with none of these symptoms).
To the extent possible, the studies listed in Table 9 provide geometric means and geometric standard deviations for measurements among the groups defined in each study. For studies reporting a geometric standard deviation along with a mean, the lower and upper 95th percentile for these distributions were derived and reported in the table.
The data provided from 15 of the 19 studies listed in Table 9 indicate that the geometric mean concentration of B2M observed among those who were not occupationally exposed to cadmium is 70-170 m g/g CRTU. Data from the 4 remaining studies indicate that exposed workers who exhibit no signs of proteinuria show mean B2MU levels of 60-300 m g/g CRTU. B2MU values in the study by Thun et al. (1989), however, appear high in comparison to the other 3 studies. If this study is removed, B2MU levels for those who are not occupationally exposed to cadmium are similar to B2MU levels found among cadmium-exposed workers who exhibit no signs of kidney dysfunction. Although the mean is high in the study by Thun et al., the range of measurements reported in this study is within the ranges reported for the other studies.
Determining a reasonable upper limit from the range of B2M concentrations observed among those who do not exhibit signs of proteinuria is problematic. Elevated B2MU levels are among the signs used to define the onset of kidney dysfunction. Without access to the raw data from the studies listed in Table 9, it is necessary to rely on reported standard deviations to estimate an upper limit for normal B2MU concentrations (i.e., the upper 95th percentile for the distributions measured). For the 8 studies reporting a geometric standard deviation, the upper 95th percentiles for the distributions are 180-1140 m g/g CRTU. These values are in general agreement with the upper 95th percentile for the distribution (i.e., 631 m g/g CRTU) reported by Buchet et al. (1980). These upper limits also appear to be in general agreement with B2MU values (i.e., 100-690 m g/g CRTU) reported as the normal upper limit by Iwao et al. (1980), Kawada et al. (1989), Wibowo et al. (1982), and Schardun and van Epps (1987). These values must be compared to levels reported among those exhibiting kidney dysfunction to define a threshold level for kidney dysfunction related to cadmium exposure.
5.3.7.2 Range of B2MU concentrations among exposed workers
Table 10 presents results from studies reporting B2MU determinations among those occupationally exposed to cadmium in the work place; in some of these studies, kidney dysfunction was observed among exposed workers, while other studies did not make an effort to distinguish among exposed workers based on kidney dysfunction. As with Table 9, this table provides geometric means and geometric standard deviations for the groups defined in each study if available. For studies reporting a geometric standard deviation along with a mean, the lower and upper 95th percentiles for the distributions are derived and reported in the table.
The data provided in Table 10 indicate that the mean B2MU concentration observed among workers experiencing occupational exposure to cadmium (but with undefined levels of proteinuria) is 160-7400 m g/g CRTU. One of these studies reports geometric means lower than this range (i.e., as low as 71 m g/g CRTU); an explanation for this wide spread in average concentrations is not available.
Seven of the studies listed in Table 10 report a range of B2MU levels among those diagnosed as having renal dysfunction. As indicated in this table, renal dysfunction (proteinuria) is defined in several of these studies by B2MU levels in excess of 300 m g/g CRTU (see footnote "c" of Table 10); therefore, the range of B2MU levels observed in these studies is a function of the operational definition used to identify those with renal dysfunction. Nevertheless, a B2MU level of 300 m g/g CRTU appears to be a meaningful threshold for identifying those having early signs of kidney damage. While levels much higher than 300 m g/g CRTU have been observed among those with renal dysfunction, the vast majority of those not occupationally exposed to cadmium exhibit much lower B2MU concentrations (see Table 9). Similarly, the vast majority of workers not exhibiting renal dysfunction are found to have levels below 300 m g/g CRTU (Table 9).
The 300 m g/g CRTU level for B2MU proposed in the above paragraph has support among researchers as the threshold level that distinguishes between cadmium-exposed workers with and without kidney dysfunction. For example, in the guide for physicians who must evaluate cadmium-exposed workers written for the Cadmium Council by Dr. Lauwerys, levels of B2M greater than 200-300 m g/g CRTU are considered to require additional medical evaluation for kidney dysfunction (exhibit 8-447, OSHA docket H057A). The most widely used test for measuring B2M (i.e., the Pharmacia Delphia test) defines B2MU levels above 300 m g/l as abnormal (exhibit L-140-1, OSHA docket H057A).
Dr. Elinder, chairman of the Department of Nephrology at the Karolinska Institute, testified at the hearings on the proposed cadmium rule. According to Dr. Elinder (exhibit L-140-45, OSHA docket H057A), the normal concentration of B2MU has been well documented (Evrin and Wibell 1972; Kjellstrom et al. 1977a; Elinder et al. 1978, 1983; Buchet et al. 1980; Jawaid et al. 1983; Kowal and Zirkes, 1983). Elinder stated that the upper 95 or 97.5 percentiles for B2MU among those without tubular dysfunction is below 300 m g/g CRTU (Kjellstrom et al. 1977a; Buchet et al. 1980; Kowal and Zirkes, 1983). Elinder defined levels of B2M above 300aeg/g CRTU as "slight" proteinuria.
5.3.8 Conclusions and Recommendations for B2MU
Based on the above evaluation, the following recommendations are made for a B2MU proficiency testing program. Note that the following discussion addresses only sampling and analysis for B2MU determinations (i.e., to be reported as an unadjusted m g B2M/l urine). Normalizing this result to creatinine requires a second analysis for CRTU (see Section 5.4) so that the ratio of the 2 measurements can be obtained.
5.3.8.1 Recommended method
The Pharmacia Delphia method (Pharmacia 1990) should be adopted as the standard method for B2MU determinations. Laboratories may adopt alternate methods, but it is the responsibility of the laboratory to demonstrate that alternate methods provide results of comparable quality to the Pharmacia Delphia method.
5.3.8.2 Data quality objectives
The following data quality objectives should facilitate interpretation of analytical results, and should be achievable based on the above evaluation.
Limit of Detection. A limit of 100 m g/l urine should be achievable, although the insert to the test kit (Pharmacia 1990) cites a detection limit of 150 m g/l; private conversations with representatives of Pharmacia, however, indicate that the lower limit of 100 m g/l should be achievable provided an additional standard of 100 m g/l B2M is run with the other standards to derive the calibration curve (Section 3.3.1.1). The lower detection limit is desirable due to the proximity of this detection limit to B2MU values defined for the cadmium medical monitoring program.
Accuracy. Because results from an interlaboratory proficiency testing program are not available currently, it is difficult to define an achievable level of accuracy. Given the general performance parameters defined by the insert to the test kits, however, an accuracy of + 15% of the target value appears achievable.
Due to the low levels of B2MU to be measured generally, it is anticipated that the analysis of creatinine will contribute relatively little to the overall variability observed among creatinine-normalized B2MU levels (see Section 5.4). The initial level of accuracy for reporting B2MU levels under this program should be set at + 15%.
Precision. Based on precision data reported by Pharmacia (1990), a precision value (i.e., CV) of 5% should be achievable over the defined range of the analyte. For internal QC samples (i.e., recommended as part of an internal QA/QC program, Section 3.3.1), laboratories should attain precision near 5% over the range of concentrations measured.
5.3.8.3 Quality assurance/quality control
Commercial laboratories providing measurement of B2MU should adopt an internal QA/QC program that incorporates the following components: Strict adherence to the Pharmacia Delphiad method, including calibration requirements; regular use of QC samples during routine runs; a protocol for corrective actions, and documentation of these actions; and, participation in an interlaboratory proficiency program. Procedures that may be used to address internal QC requirements are presented in Attachment 1. Due to differences between analyses for B2MU and CDB/CDU, specific values presented in Attachment 1 may have to be modified. Other components of the program (including characterization runs), however, can be adapted to a program for B2MU.
5.4 Monitoring Creatinine in Urine (CRTU)
Because CDU and B2MU should be reported relative to concentrations of CRTU, these concentrations should be determined in addition CDU and B2MU determinations.
5.4.1 Units of CRTU Measurement
CDU should be reported as m g Cd/g CRTU, while B2MU should be reported as m g B2M/g CRTU. To derive the ratio of cadmium or B2M to creatinine, CRTU should be reported in units of g crtn/l of urine. Depending on the analytical method, it may be necessary to convert results of creatinine determinations accordingly.
5.4.2 Analytical Techniques Used to Monitor CRTU
Of the techniques available for CRTU determinations, an absorbance spectrophotometric technique and a high-performance liquid chromatography (HPLC) technique are identified as acceptable in this protocol.
5.4.3 Methods Developed for CRTU Determinations
CRTU analysis performed in support of either CDU or B2MU determinations should be performed using either of the following 2 methods:
1. The Du Pont method (i.e., Jaffe method), in which creatinine in a sample reacts with picrate under alkaline conditions, and the resulting red chromofore is monitored (at 510 nm) for a fixed interval to determine the rate of the reaction; this reaction rate is proportional to the concentration of creatinine present in the sample (a copy of this method is provided in Attachment 2 of this protocol); or,
2. the OSHA SLC Technical Center (OSLTC) method, in which creatinine in an aliquot of sample is separated using an HPLC column equipped with a UV detector; the resulting peak is quantified using an electrical integrator (a copy of this method is provided in Attachment 3 of this protocol).
5.4.4 Sample Collection and Handling
CRTU samples should be segregated from samples collected for CDU or B2MU analysis. Sample-collection techniques have been described under Section 5.2.4. Samples should be preserved either to stabilize CDU (with HNO 3) or B2MU (with NaOH). Neither of these procedures should adversely affect CRTU analysis (see Attachment 3).
5.4.5 General Method Performance
Data from the OSLTC indicate that a CV of 5% should be achievable using the OSLTC method (Septon, L private communication). The achievable accuracy of this method has not been determined.
Results reported in surveys conducted by the CAP (CAP 1991a, 1991b and 1992) indicate that a CV of 5% is achievable. The accuracy achievable for CRTU determinations has not been reported.
Laboratories performing creatinine analysis under this protocolshould be CAP accredited and should be active participants in the CAP surveys.
5.4.6 Observed CRTU Concentrations
Published data suggest the range of CRTU concentrations is 1.0-1.6 g in 24-hour urine samples (Harrison 1987). These values are equivalent to about 1 g/l urine.
5.4.7 Conclusions and Recommendations for CRTU
5.4.7.1 Recommended method
Use either the Jaffe method (Attachment 2) or the OSLTC method (Attachment 3). Alternate methods may be acceptable provided adequate performance is demonstrated in the CAP program.
5.4.7.2 Data quality objectives
Limit of Detection. This value has not been formally defined; however, a value of 0.1 g/l urine should be readily achievable.
Accuracy. This value has not been defined formally; accuracy should be sufficient to retain accreditation from the CAP.
Precision. A CV of 5% should be achievable using the recommended methods.
6.0 REFERENCES
Adamsson E, Piscator M, and Nogawa K. (1979). Pulmonary and gastrointestinal exposure to cadmium oxide dust in a battery factory. Environmental Health Perspectives, 28, 219-222.
American Conference of Governmental Industrial Hygienists (ACGIH). (1986). Documentation of the Threshold Limit Values and Biological Exposure Indices. 5th edition. p. BEI-55.
Bernard A, Buchet J, Roels H, Masson P, and Lauwerys R. (1979). Renal excretion of proteins and enzymes in workers exposed to cadmium. European Journal of Clinical Investigation, 9, 11-22.
Bernard A and Lauwerys R. (1990). Early markers of cadmium nephrotoxicity: Biological significance and predictive value. Toxocological and Environmental Chemistry, 27, 65-72.
Braunwald E, Isselbacher K, Petersdorf R, Wilson J, Martin J, and Fauci A (Eds.). (1987). Harrison's Principles of Internal Medicine. New York: McGraw-Hill Book Company.
Buchet J, Roels H, Bernard I, and Lauwerys R. (1980). Assessment of renal funcion of workers exposed to inorganic lead, cadmium, or mercury vapor. Journal of Occupational Medicine, 22, 741-750.
CAP. (1991). Urine Chemistry, Series 1: Survey (Set U-B). College of American Pathologists.
CAP. (1991). Urine Chemistry, Series 1: Survey (Set U-C). College of American Pathologists.
CAP. (1992). Urine Chemistry, Series 1: Survey (Set U-A). College of American Pathologists.
CDC. (1986). Centers for Disease Control, Division of Environmental Health Laboratory Sciences, Center for Environmental Health, Atlanta, Georgia. Docket No. 106A. Lake Couer d'Alene, Idaho cadmium and lead study: 86-0030, Specimen collection and shipping protocol.
CDC. (1990). Centers for Disease Control, Nutritional Biochemistry Branch. 4/27/90 Draft SOP for Method 0360A "Determination of cadmium in urine by graphite furnace atomic absorption spectrometry with Zeeman background correction.
Centre de Toxicologie du Quebec. (1991). Interlaboratory comparison program report for run # 2. Shipping date 3/11/91. Addition BLR 9/19.
Chia K, Ong C, Ong H, and Endo G. (1989). Renal tubular function of workers exposed to low levels of cadmium. British Journal of Industrial Medicine, 46, 165-170.
Claeys-Thoreau F. (1982). Determination of low levels of cadmium and lead in biological fluids with simple dilution by atomic absorption spectrophotometry using Zeeman effect background absorption and the L'Vov platform. Atomic Spectroscopy, 3, 188-191.
DeBenzo Z, Fraile R, and Carrion N. (1990). Electrothermal atomization atomic absorption spectrometry with stabilized aqueous standards for the determination of cadmium in whole blood. Analytica Chimica Acta, 231, 283-288.
Elinder C, Edling C, Lindberg E, Kagedal B, and Vesterberg O. (1985). Assessment of renal function in workers previously exposed to cadmium. British Journal of Internal Medicine, 42, 754.
Ellis K, Cohn S, and Smith T. (1985). Cadmium inhalation exposure estimates: Their significance with respect to kidney and liver cadmium burden. Journal of Toxicology and Environmental Health, 15, 173-187.
Ellis K, Yasumura S, Vartsky D, and Cohn S. (1983). Evaluation of biological indicators of body burden of cadmium in humans. Fundamentals and Applied Toxicology, 3, 169-174.
Ellis K, Yeun K, Yasumura S, and Cohn S. (1984). Dose-response analysis of cadmium in man: Body burden vs kidney function. Environmental Research, 33, 216-226.
Evrin P, Peterson A, Wide I, and Berggard I. (1971). Radioimmunoassay of B-2- microglobulin in human biological fluids. Scandanavian Journal of Clinical Laboratory Investigation, 28, 439-443.
Falck F, Fine L, Smith R, Garvey J, Schork A, England B, McClatchey K, and Linton J. (1983).
Metallothionein and occupational exposure to cadmium. British Journal of Industrial Medicine, 40, 305-313.
Federal Register. (1990). Occupational exposure to cadmium: Proposed rule. 55/22/4052-4147, February 6.
Friberg, Exhibit 29, (1990). Exhibit No. 29 of the OSHA Federal Docket H057A. Washington, D.C.
Friberg L. (1988). Quality assurance. In T. Clarkson (Ed.), Biological Monitoring of Toxic Metals (pp. 103-105). New York: Plenum Press.
Friberg L, and Elinder C. (1988). Cadmium toxicity in humans. In Essential and Trace Elements in Human Health and Disease (pp. 559-587). Docket Number 8-660.
Friberg L, Elinder F, et al. (1986). Cadmium and Health: A Toxicological and Epidemiological Appraisal. Volume II, Effects and Response. Boca Raton, FL: CRC Press.
Friberg L, Piscator M, Nordberg G, and Kjellstrom T. (1974). Cadmium in the Environment (2nd ed.). Cleveland:CRC.
Friberg L and Vahter M. (1983). Assessment of exposure to lead and cadmium through biological monitoring: Results of a UNEP/WHO global study. Environmental Research, 30, 95-128.
Gunter E, and Miller D. (1986). Laboratory procedures used by the division of environmental health laboratory sciences center for environmental health, Centers for Disease Control for the hispanic health and nutrition examination survey (HHANES). Atlanta, GA: Centers for Disease Control.
Harrison. (1987). Harrison's Principles of Internal Medicine. Braunwald, E; Isselbacher, KJ; Petersdorf, RG; Wilson, JD; Martin, JB; and Fauci, AS Eds. Eleventh Ed. McGraw Hill Book Company. San Francisco.
Henry J. (1991). Clinical Diagnosis and Management by Laboratory Methods (18th edition). Philadelphia: WB Saunders Company.
IARC (1987). IRAC Monographs on the Evaluation of Carcinogenic Risks to Humans. Overall Evaluation of Carcinogenicity: Update of Volume 1-42. Supplemental 7, 1987.
Ishizaki M, Kido T, Honda R, Tsuritani I, Yamada Y, Nakagawa H, and Nogawa K. (1989). Dose-response relationship between urinary cadmium and B-2- Microglobulin in a Japanese environmentally cadmium exposed population. Toxicology, 58, 121-131.
Iwao S, Tsuchiya K, and Sakurai H. (1980). Serum and urinary B-2-microglobulin among cadmium-exposed workers. Journal of Occupational Medicine, 22, 399-402.
Iwata K, Katoh T, Morikawa Y, Aoshima K, Nishijo M, Teranishi H, and Kasuya M. (1988). Urinary trehalase aciviy as an indicaor of kidney injury due to environmental cadmium exposure. Archives of Toxicology, 62, 435-439.
Kawada T, Koyama H, and Suzuki S. (1989). Cadmium, NAG activity, and B-2- microglobulin in the urine of cadmium pigment workers. British Journal of Industrial Medicine, 46, 52-55.
Kawada T, Tohyama C, and Suzuki S. (1990). Significance of the excretion of urinary indicator proteins for a low level of occupational exposure to cadmium. International Archives of Occupational Environmental Health, 62, 95-100.
Kjellstrom T. (1979). Exposure and accumulation of cadmium in populations from Japan, the United States, and Sweden. Environmental Health Perspectives, 28, 169-197.
Kjellstrom T, Evrin P, and Rahnster B. (1977). Dose-response analysis of cadmium-induced tubular proteinuria. Environmental Research, 13, 303-317.
Kjellstrom T, Shiroishi K, and Evrin P. (1977). Urinary B-2- microglobulin excretion among people exposed to cadmium in the general environment. Environmental Research, 13, 318-344.
Kneip T, & Crable J (Eds.). (1988). Method 107. Cadmium in blood. Methods for biological monitoring (pp. 161-164).
Washington, DC: American Public Health Association.
Kowal N. (1988). Urinary cadmium and B-2-microglobulin: Correlation with nutrition and smoking history. Journal of Toxicology and Environmental Health, 25, 179-183.
Kowal N, Johnson D, Kraemer D, and Pahren H. (1979). Normal levels of cadmium in diet, urine, blood, and tissues of inhabitants of the United States. Journal of Toxicology and Environmental Health, 5, 995-1014.
Kowal N and Zirkes M. (1983). Urinary cadmium and B-2-microglobulin: Normal values and concentration adjustment. Journal of Toxicology and Environmental Health, 11, 607-624.
Lauwerys R, Buchet J, and Roels H. (1976). The relationship between cadmium exposure or body burden and the concentration of cadmium in blood and urine in man. International Archives of Occupational and Environmental Health, 36, 275- 285
Lauwerys R, Roels H, Regniers, Buchet J, and Bernard A. (1979). Significance of cadmium concentration in blood and in urine in workers exposed to cadmium.
Environmental Research, 20, 375-391.Lind B, Elinder C, Friberg L, Nilsson B, Svartengren M, and Vahter M. (1987). Quality control in the analysis of lead and cadmium in blood. Fresenius' Zeitschrift fur Analytical Chemistry, 326, 647-655.
Mason H, Davison A, Wright A, Guthrie C, Fayers P, Venables K, Smith N, Chettle D, Franklin D, Scott M, Holden H, Gompertz D, and Newman-Taylor A. (1988). Relations between liver cadmium, cumulative exposure, and renal function in cadmium alloy workers. British Journal of Industrial Medicine, 45, 793-802.
Meridian Research, Inc. (1989). Quantitative Assessment of Cancer Risks Associated with Occupational Exposure to Cd. Prepared by Meridian Research, Inc. and Roth Associates, Inc. for the Occupational Safety & Health Administration. June 12, 1989.
Meridian Research, Inc and Roth Associates, Inc. (1989). Quantitative Assessment of the Risk of Kidney Dysfunction Associated with Occupational Exposure to Cd. Prepared by Meridian Research, Inc. and Roth Associates, Inc. for the Occupational Safety & Health Administration. July 31 1989.
Micheils E and DeBievre P. (1986). Method 25-Determination of cadmium in whole blood by isotope dilution mass spectrometry. O'Neill I, Schuller P, and Fishbein L (Eds.), Environmental Carcinogens Selected Methods of Analysis (Vol. 8). Lyon, France: International Agency for Research on Cancer.
Mueller P, Smith S, Steinberg K, and Thun M. (1989). Chronic renal tubular effects in relation to urine cadmium levels. Nephron, 52, 45-54.
NIOSH. (1984a). Elements in blood or tissues. Method 8005 issued 5/15/85 and Metals in urine. Method 8310 issued 2/15/84 In P. Eller (Ed.), NIOSH Manual of Analytical Methods (Vol. 1, Ed. 3). Cincinnati, Ohio: US-DHHS.
NIOSH. (1984b). Lowry L. Section F: Special considerations for biological samples in NIOSH Manual of Analytical Methods (Vol. 1, 3rd ed). P. Eller (Ed.). Cincinnati, Ohio: US-DHHS.
Nordberg G and Nordberg M. (1988). Biological monitoring of cadmium. In T. Clarkson, L. Friberg, G. Nordberg, and P. Sager (Eds.),Biological Monitoring of Toxic Metals, New York: Plenum Press.
Nogawa K. (1984). Biologic indicators of cadmium nephrotoxicity in persons with low-level cadmium exposure. Environmental Health Perspectives, 54, 163-169.
OSLTC (no date). Analysis of Creatinine for the Normalization of Cadmium and Beta-2-Microglobulin Concentrations in Urine. OSHA Salt Lake Technical Center. Salt Lake City, UT.
Paschal. (1990). Attachment 8 of exhibit 106 of the OSHA docket H057A.
Perkin-Elmer Corporation. (1982). Analytical Methods for Atomic Absorption Spectroscopy.
Perkin-Elmer Corporation. (1977). Analytical Methods Using the HGA Graphite Furnace.
Pharmacia Diagnostics. (1990). Pharmacia DELFIA system B-2- microglobulin kit insert. Uppsala, Sweden: Pharmacia Diagnostics.
Piscator M. (1962). Proteinuria in chronic cadmium poisoning. Archives of Environmental Health, 5, 55-62.
Potts, C.L. (1965). Cadmium Proteinuria -The Health Battery Workers Exposed to Cadmium Oxide dust. Ann Occup Hyg, 3:55-61, 1965.
Princi F. (1947). A study of industrial exposures to cadmium. Journal of Industrial Hygiene and Toxicology, 29, 315-320.
Pruszkowska E, Carnick G, and Slavin W. (1983). Direct determination of cadmium in urine with use of a stabilized temperature platform furnace and Zeeman background correction. Clinical Chemistry, 29, 477-480.
Roberts C and Clark J. (1986). Improved determination of cadmium in blood and plasma by flameless atomic absorption spectroscopy. Bulletin of Environmental Contamination and Toxicology, 36, 496-499.
Roelandts I. (1989). Biological reference materials. Soectrochimica Acta, 44B, 281-290.
Roels H, Buchet R, Lauwerys R, Bruaux P, Clays-Thoreau F, Laafontaine A, Overschelde J, and Verduyn J. (1978). Lead and cadmium absorption among children near a nonferrous metal plant. Environmental Research, 15, 290-308.
Roels H, Djubgang J, Buchet J, Bernard A, and Lauwerys R. (1982). Evolution of cadmium-induced renal dysfunction in workers removed from exposure. Scandanavian Journal of Work and Environmental Health, 8, 191-200.
Roels H, Lauwerys R, and Buchet J. (1989). Health significance of cadmium induced renal dysfunction: A five year follow-up. British Journal of Industrial Medicine, 46, 755-764.
Roels J. Lauwerys R, Buchet J, Bernard A, Chettle D, Harvey T, and Al-Haddad I. (1981). In vivo measurements of liver and kidney cadmium in workers exposed to this metal: Its significance with respect to cadmium in blood and urine. Environmental Research, 26, 217-240.
Roels H, Lauwerys R, Buchet J, Bernard A, Lijnen P, and Houte G. (1990). Urinary kallikrein activity in workers exposed to cadmium, lead, or mercury vapor. British Journal of Industrial Medicine, 47, 331-337.
Sakurai H, Omae K, Toyama T, Higashi T, and Nakadate T. (1982).Cross-sectional study of pulmonary function in cadmium alloy workers. Scandanavian Journal of Work and Environmental Health, 8, 122-130.
Schardun G and van Epps L. (1987). B-2-microglobulin: Its significance in the evaluation of renal function. Kidney International, 32, 635-641.
Shaikh Z, and Smith L. (1984). Biological indicators of cadmiumexposure and toxicity. Experentia, 40, 36-43.
Smith J and Kench J. (1957). Observations on urinary cadmium and protein excretion in men exposed to cadmium oxide dust and fume. British Journal of Industrial Medicine, 14, 240-245.
Smith J, Kench J, and Lane R. (1955). Determination of Cadmium in urine and observations on urinary cadmium and protein excretion in men exposed to cadmium oxide dust. British Journal of Industrial Medicine, 12, 698-701.
SWRI (Southwest Research Institute). (1978). The distribution of cadmium and other metals in human tissues. Health Effects Research Lab, Research Triangle Park, NC, Population Studies Division. NTIS No. PB-285-200.
Stewart M and Hughes E. (1981). Urinary B-2-microglobulin in the biological monitoring of cadmium workers. British Journal of Industrial Medicine, 38, 170- 174.
Stoeppler K and Brandt M. (1980). Contributions to automated trace analysis. Part V. Determination of cadmium in whole blood and urine by electrothermal atomic absorption spectrophotometry. Fresenius' Zeitschrift fur Analytical Chemistry, 300, 372-380.
Takenaka et al. (1983). Carcinogencity of Cd Chloride Aerosols in White Rates. INCI 70: 367-373, 1983.
Thun M, Osorio A, Schober S, Hannon W, Lewis B, and Hal- perin W. (1989). Nephropathy in cadmium workers: Assessment of risk from airborne occupational exposure to cadmium. British Journal of Industrial Medicine, 46, 689-697.
Thun M, Schnorr T, Smith A, Halperin W, and Lemen R. (1985). Mortality among a cohort of US cadmium production workers -an update. Journal of the National Cancer Institute, 74, 325-333.
Travis D and Haddock A. (1980). Interpretation of the observed age-dependency of cadmium body burdens in man. Environmental Research, 22, 46-60.
Tsuchiya K. (1967). Proteinuria of workers exposed to cadmium fume. Archives of Environmental Health, 14, 875-880.
Tsuchiya K. (1976). Proteinuria of cadmium workers. Journal of Occupational Medicine, 18, 463-470.
Tsuchiya K, Iwao S, Sugita M, Sakurai H. (1979). Increased urinary B-2- microglobulin in cadmium exposure: Dose-effect relationship and biological significance of B-2-microglobulin. Environmental Health Perspectives, 28, 147- 153.
USEPA. (1985). Updated Mutagenicity and Carcinogenicity Assessments of Cd: Addendum to the Health Assessment Document for Cd (May 1981). Final Report. June 1985.
Vahter M and Friberg L. (1988). Quality control in integrated human exposure monitoring of lead and cadmium. Fresenius' Zeitschrift fur Analytical Chemistry, 332, 726-731.
Weber J. (1988). An interlaboratory comparison programme for several toxic substances in blood and urine. The Science of the Total Environment, 71, 111- 123.
Weber J. (1991a). Accuracy and precision of trace metal determinations in biological fluids. In K. Subramanian, G. Iyengar, and K. Okamot (Eds.), Biological Trace Element Research-Multidisciplinary Perspectives, ACS Symposium Series 445. Washington, DC: American Chemical Society.
Weber J. (1991b). Personal communication about interlaboratory program and shipping biological media samples for cadmium analyses.
Wibowo A, Herber R, van Deyck W, and Zielhuis R. (1982). Biological assessment of exposure in factories with second degree usage of cadmium compounds. International Archives of Occupational Environmental Health, 49, 265-273.
ATTACHMENT 1: NONMANDATORY PROTOCOL FOR AN INTERNAL QUALITY ASSURANCE/QUALITY CONTROL PROGRAM
The following is an example of the type of internal quality assurance/quality control program that assures adequate control to satisfy mandatory OSHA requirements under this protocol. However, other approaches may also be acceptable.
As indicated in Section 3.3.1 of the protocol, the mandatory QA/QC program for CDB and CDU should address, at a minimum, the following:
<> calibration;
<> establishment of control limits;
<> internal QC analyses and maintaining control; and
<> corrective action protocols.
This illustrative program includes both initial characterization runs to establish the performance of the method and ongoing analysis of quality control samples intermixed with compliance samples to maintain control.
CALIBRATION
Before any analytical runs are conducted, the analytic instrument must be calibrated. This is to be done at the beginning of each day on which quality control samples and/or compliance samples are run. Once calibration is established, quality control samples or compliance samples may be run. Regardless of the type of samples run, every fifth sample must be a standard to assure that the calibration is holding.
Calibration is defined as holding if every standard is within plus or minus ( +) 15% of its theoretical value. If a standard is more than plus or minus 15% of its theoretical value, then the run is out of control due to calibration error and the entire set of samples must either be reanalyzed after recalibrating or results should be recalculated based on a statistical curve derived from the measurement of all standards.
It is essential that the highest standard run is higher than the highest sample run. To assure that this is the case, it may be necessary to run a high standard at the end of the run, which is selected based on the results obtained over the course of the run.
All standards should be kept fresh, and as they get old, they should be compared with new standards and replaced.
INITIAL CHARACTERIZATION RUNS AND ESTABLISHING CONTROL
A participating laboratory should establish four pools of quality control samples for each of the analytes for which it wishes to be accredited. The concentrations of quality control samples within each pool are to be centered around each of the four target levels for the particular analyte identified in Section 4.4 of the protocol.
Within each pool, at least 4 quality control samples need to be established with varying concentrations ranging between plus or minus 50% of the target value of that pool. Thus for the medium-high cadmium in blood pool, the theoretical values of the quality control samples may range from 5 to 15 m g/l, (the target value is m 10 g/l). At least 4 unique theoretical values must be represented in this pool.
The range of theoretical values of plus or minus 50% of the target value of a pool means that there will be overlap of the pools. For example, the range of values for the medium-low pool for cadmium in blood is 3.5 to 10.5 m g/l while the range of values for the medium-high pool is 5 to 15 m g/l. Therefore, it is possible for a quality control sample from the medium-low pool to have a higher concentration of cadmium than a quality control sample from the medium-high pool.
Quality control samples may be obtained as commercially available reference materials, internally prepared, or both. Internally prepared samples should be well characterized and traced or compared to a reference material for which a consensus value for concentration is available. Levels of analyte in the quality control samples must be concealed from the analyst prior to the reporting of analytical results. Potential sources of materials that may be used to construct quality control samples are listed in Section 3.3.1 of the protocol.
Before any compliance samples are analyzed, control limits must be established. Control limits should be calculated for every pool of each analyte for which a laboratory seeks accreditation, and control charts should be kept for each pool of each analyte. A separate set of control charts and control limits should be established for each analytical instrument in a laboratory that will be used for analysis of compliance samples.
At the beginning of this QA/QC program, control limits should be based on the results of the analysis of 20 quality control samples from each pool of each analyte. For any given pool, the 20 quality control samples should be run on 20 different days. Although no more than one sample should be run from any single pool on a particular day, a laboratory may run quality control samples from different pools on the same day. This constitutes a set of initial characterization runs.
For each quality control sample analyzed, the value F/T (defined in the glossary) should be calculated. To calculate the control limits for a pool of an analyte, it is first necessary to calculate the mean, X, of the F/T values for each quality control sample in a pool and then to calculate its standard deviation -- S. Thus, for the control limit for a pool, X is calculated as:
and -- S is calculated as
where N is the number of quality control samples run for a pool.
The control limit for a particular pool is then given by the mean plus or minus 3 standard deviations (X + 3 -- S).
The control limits may be no greater than 40% of the mean F/T value. If three standard deviations are greater than 40% of the mean F/T value, then analysis of compliance samples may not begin [FN1]. Instead, an investigation into the causes of the large standard deviation should begin, and the inadequacies must be remedied. Then, control limits must be reestablished which will mean repeating the running 20 quality control samples from each pool over 20 days.
[FN1] Note that the value, "40%" may change over time as experience is gained with the program.
INTERNAL QUALITY CONTROL ANALYSES AND MAINTAINING CONTROL
Once control limits have been established for each pool of an analyte, analysis of compliance samples may begin. During any run of compliance samples, quality control samples are to be interspersed at a rate of no less than 5% of the compliance sample workload. When quality control samples are run, however, they should be run in sets consisting of one quality control sample from each pool. Therefore, it may be necessary, at times, to intersperse quality control samples at a rate greater than 5%.
There should be at least one set of quality control samples run with any analysis of compliance samples. At a minimum, for example, 4 quality control samples should be run even if only 1 compliance sample is run. Generally, the number of quality control samples that should be run are a multiple of four with the minimum equal to the smallest multiple of four that is greater than 5% of the total number of samples to be run. For example, if 300 compliance samples of an analyte are run, then at least 16 quality control samples should be run (16 is the smallest multiple of four that is greater than 15, which is 5% of 300).
Control charts for each pool of an analyte (and for each instrument in the laboratory to be used for analysis of compliance samples) should be established by plotting F/T versus date as the quality control sample results are reported. On the graph there should be lines representing the control limits for the pool, the mean F/T limits for the pool, and the theoretical F/T of 1.000. Lines representing plus or minus ( +) 2 S should also be represented on the charts. A theoretical example of a control chart is presented in Figure 1
FIGURE 1
THEORETICAL EXAMPLE OF A CONTROL CHART FOR A POOL OF AN ANALYTE
_______________________________________ 1.162 (Upper Control Limit)
x 1.096 (Upper 2 S Line)
---------------------------------------
x
x 1.000 (Theoretical Mean)
---------------------------------------
x x 0.964 (Mean)
---------------------------------------
x x
x
x .832 (Lower 2 S Line)
---------------------------------------
x 0.766 (Lower Control Limit)
---------------------------------------
March 2 2 3 5 6 9 10 13 16 17
All quality control samples should be plotted on the chart, and the charts should be checked for visual trends. If a quality control sample falls above or below the control limits for its pool, then corrective steps must be taken (see the section on corrective actions below). Once a laboratory's program has been established, control limits should be updated every 2 months, prior to sending OSHA the updated data required to maintain accreditation.
The updated control limits should be calculated from the results of the last 100 quality control samples run for each pool. If 100 quality control samples from a pool have not been run at the time of the update, then the limits should be based on as many as have been run provided at least 20 quality control samples from each pool have been run over 20 different days.
The trends that should be looked for on the control charts are:
1. 10 consecutive quality control samples falling above or below the mean;
2. 3 consecutive quality control samples falling more than 2 S from the mean (above or below the 2 S lines of the chart); or
3. the mean calculated to update the control limits falls more than 10% above or below the theoretical mean of 1.000.
If any of these trends is observed, then all analysis must be stopped, and an investigation into the causes of the errors must begin. Before the analysis of compliance samples may resume, the inadequacies must be remedied and the control limits must be reestablished for that pool of an analyte. Reestablishment of control limits will entail running 20 sets of quality control samples over 20 days.
Note that alternative procedures for defining internal quality control limits may also be acceptable. Limits may be based, for example, on proficiency testing, such as + 1 m g or 15% of the mean (whichever is greater). These should be clearly defined.
CORRECTIVE ACTIONS
Corrective action is the term used to describe the identification and remediation of errors occurring within an analysis. Corrective action is necessary whenever the result of the analysis of any quality control sample falls outside of the established control limits. The steps involved may include simple things like checking calculations of basic instrument maintenance, or it may involve more complicated actions like major instrument repair. Whatever the source of error, it must be identified and corrected (and a Corrective Action Report (CAR) must be completed and sent to OSHA with the next reaccreditation).
To maintain accreditation, laboratories must report corrective actions to the OSHA Salt Lake Technical Center. A form to be used for reporting corrective actions is provided in Attachment 5 of the protocol.
Attachment 2:
CREATININE IN URINE (JAFFE PROCEDURE)
INTENDED USE: The CREA pack is used in the Du Pont ACA [ discrete clinical analyzer to quantitatively measure creatinine in serum and urine.
SUMMARY: The CREA method employs a modification of the kinetic Jaffe reaction reported by Larsen. This method has been reported to be less susceptible than conventional methods to interference from non-creatinine, Jaffe-positive compounds. [FN1]
A split sample comparison between the CREA method and a conventional Jaffe procedure on Autoanalyzer [ showed a good correlation. (See SPECIFIC PERFORMANCE CHARACTERISTICS).
Autoanalyzer, [ is a registered trademark of Technicon Corp., Tarrytown, NY.
PRINCIPLES OF PROCEDURE: In the presence of a strong base such as NaOH, picrate reacts with creatinine to form a red chromophore. The rate of increasing absorbance at 510 nm due to the formation of this chromophore during a 17.07- second measurement period is directly proportional to the creatinine concentration in the sample.
REAGENTS:
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________ (continued)