Loading (50 kb)...'
(continued) .32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations are the same for TSS and pH as specified in §415.662.
Subpart BO—Zinc Chloride Production Subcategory
top
Source: 49 FR 33428, Aug. 22, 1984, unless otherwise noted.
§ 415.670 Applicability; description of the zinc chloride production subcategory.
top
The provisions of this subpart are applicable to discharges and to the introduction of pollutants into treatment works which are publicly owned resulting from the production of zinc chloride.
§ 415.671 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations, and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product shall mean zinc chloride.
(c) The term arsenic shall mean the total arsenic present in the process wastewater stream exiting the wastewater treatment system.
(d) The term zinc shall mean the total zinc present in the process wastewater stream exiting the wastewater treatment system.
(e) The term lead shall mean the total lead present in the process wastewater stream exiting the wastewater treatment system.
§ 415.672 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
top
(a) Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
Subpart BO_Zinc Chloride
------------------------------------------------------------------------
BPT effluent limitations
---------------------------
Average of
Pollutant or pollutant property daily values
Maximum for for 30
any 1 day consecutive
days
------------------------------------------------------------------------
Milligrams
per liter
(mg/l)
---------------------------
TSS......................................... 43 25
Arsenic (T)................................. 3.0 1.0
Zinc (T).................................... 11.4 3.8
Lead (T).................................... 1.8 0.6
pH.......................................... (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 10.0
[49 FR 33428, Aug. 22, 1984; 49 FR 37594, Sept. 25, 1984]
§ 415.673 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
top
Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
Subpart BO_Zinc Chloride
------------------------------------------------------------------------
BAT effluent limitations
-----------------------------
Average of
Pollutant or pollutant property daily values
Maximum for for 30
any 1 day consecutive
days
------------------------------------------------------------------------
Milligrams
per liter (mg/
l)
-----------------------------
Arsenic (T)............................... 3.0 1.0
Zinc (T).................................. 2.3 0.76
Lead (T).................................. 0.18 0.048
------------------------------------------------------------------------
[49 FR 33428, Aug. 22, 1984; 49 FR 37594, Sept. 25, 1984]
§ 415.674 Pretreatment standards for existing sources (PSES).
top
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources (PSES):
Subpart BO_Zinc Chloride
------------------------------------------------------------------------
PSES effluent limitations
-----------------------------
Average of
Pollutant or pollutant property daily values
Maximum for for 30
any 1 day consecutive
days
------------------------------------------------------------------------
Milligrams
per liter (mg/
l)
-----------------------------
Arsenic (T)............................... 3.0 1.0
Zinc (T).................................. 2.3 0.76
Lead (T).................................. 0.18 0.048
------------------------------------------------------------------------
[49 FR 33428, Aug. 22, 1984; 49 FR 37594, Sept. 25, 1984]
§ 415.675 New source performance standards (NSPS):
top
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
Subpart BO_Zinc Chloride
------------------------------------------------------------------------
NSPS effluent limitations
-----------------------------
Average of
Pollutant or pollutant property daily values
Maximum for for 30
any 1 day consecutive
days
------------------------------------------------------------------------
Milligrams
per liter (mg/
l)
-----------------------------
TSS....................................... 28 17
Arsenic (T)............................... 3.0 1.0.
Zinc (T).................................. 2.3 0.76
Lead (T).................................. 0.18 0.048
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 10.0.
[49 FR 33428, Aug. 22, 1984; 49 FR 37594, Sept. 25, 1984]
§ 415.676 Pretreatment standards for new sources (PSNS).
top
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources (PSNS): The limitations for arsenic (T), zinc (T), and lead (T) are the same as specified in §415.674.
§ 415.677 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must acheive the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations are the same for TSS and pH as specified in §415.672.