Loading (50 kb)...'
(continued) of gross
cane)
-----------------------------
BOD5...................................... 1.14 0.63
TSS....................................... 1.41 0.47
pH........................................ (\1\) (\1\)
------------------------------------------------------------------------
\1\ Within the range 6.0 to 9.0.
(b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributable to the barometric condenser cooling water to that amount of BOD5 attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.
------------------------------------------------------------------------
Effluent limitations, the total
of the daily values for the
Effluent characteristic entire discharge period shall
not exceed_
------------------------------------------------------------------------
Metric units (kg/kkg of gross
cane)
---------------------------------
BOD5.................................. 0.63.
TSS................................... 0.47.
pH.................................... Within the range 6.0 to 9.0.
---------------------------------
English units (lb/1,000 lb of
gross cane)
---------------------------------
BOD5.................................. 0.63.
TSS................................... 0.47.
pH.................................... Within the range 6.0 to 9.0.
------------------------------------------------------------------------
(Secs. 301, 304 (b) and (c), 306 (b) and (c), 307 (c) and (d) of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c) and 1326(c)), 86 Stat. 816 et seq., Pub. L. 92–500)
[40 FR 8504, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]
§ 409.87 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §409.82 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 24999, July 9, 1986]